Descargar Imprimir esta página

Cosmetal HI CLASS AC Instalación Uso Y Mantenimiento página 19

Publicidad

IT
TIPO DI ALLARME
01 / 01 / 2016
09 : 02
TANICA PIENA
APRIRE MOBILE
E
C
O
01 / 01 / 2016
09 : 02
VUOTARE TANICA
REINSERIRE TUBO
E
C
O
Interviene quando la tanica den-
tro il mobile è piena di acqua di
scarico.
01 / 01 / 2016
09 : 02
SANIFICAZIONE
ENTRO 15 GIORNI
E
C
O
01 / 01 / 2016
09 : 02
SANIFICAZIONE
NECESSARIA
E
C
O
Se è impostato, il "Calendario Sa-
SOLUZIONE
Vuotare la tanica e riposizionarla
correttamente nella sue sede dentro
il mobiletto avendo cura di reinserire
correttamente il tubo dentro l'imboc-
co della tanica.
Contattare servizio di assistenza per
azzerare il "Contatore Giorni di Sa-
cendere la macchina.
EN
ALARM MESSAGE
01 / 01 / 2016
NO WATER
E
C
O
On WG versions a safety system
stops the carbonation pump if it
runs for more than 4 minutes, and
also disables the operation of the
carbonated water solenoid valve.
CALL SERVICE
01 / 01 / 2016
PROBE ALARM
-
ICE BANK
E
C
O
Displayed when the temperature
probe is malfunctioning and:
• Temperature readings are in-
• Cooling cycles do not work
• If the temperature values are
outside the established limits.
CALL SERVICE
01 / 01 / 2016
PROBE ALARM
HOT TANK
E
C
O
Displayed when the temperature
probe is malfunctioning and:
• Temperature readings are in-
• A correct management of the
• If the temperature values are
outside the established limits.
CALL SERVICE
01 / 01 / 2016
ALARM COMPRESSOR
E
C
O
Advises that the compressor has
not managed to reach the set
temperature after 12 hours of
functioning.
CALL SERVICE
SOLUTION
MAKE SURE:
09 : 02
• that the hydraulic circuit is prop-
• that the level probe in the carbon-
• that the stainless steel coil is not
• that the pump is not blocked or
obstructed.
It will not be possible to draw car-
bonated water until the cause of the
problem has been removed.
Once the cause of the problem is
removed, switch the water cooler off
and on again to resume operation.
MAKE SURE:
09 : 02
• That there is electrical continuity
in the temperature sensor (use a
• That the temperature sensor is
electrically connected.
It will not be possible to draw cold
carbonated or still water until the
cause of the problem has been re-
will not work.
Once the cause of the problem is
removed, switch the water cooler off
and on again to resume operation.
MAKE SURE:
09 : 02
• That there is electrical continuity
in the temperature sensor (use a
• That the temperature sensor is
electrically connected.
Hot water cannot be dispensed
until the problem is resolved. Fur-
thermore, the heating function is
blocked.
Once the cause of the problem is
removed, switch the water cooler off
and on again to resume operation.
Contact the assistance service to
09 : 02
check the cause of the malfunction-
ing of the compressor:
• Make sure that no electrical wire
that feeds the compressor has
• Make sure that there no gas leaks
in the refrigerant circuit or if the
compressor is defective.
Once the problem has been re-
solved, switch off and then switch on
the machine to eliminate the alarm
screen.