Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
Fault/ cause/ remedy
Fault
Water not flowing
Indicator lamp
flashes
Water flowing
continuously
Undesired /
excessively long
water flow
Flow rate too low
Water temperature
too high or too low
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk
Cause
• Battery without contact
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve
without contact
• Battery discharged
• Battery almost discharged
• Cleaning mode active
• Solenoid valve defective
• Detection zone of sensor system set too
high for local conditions (undesirable
reflection)
• Isolating valves not fully open
• Water supply restricted
• Filter upstream of solenoid valve dirty
• Flow straightener dirty
• Filters in the union connection set
blocked
• Thermostat not adjusted to local pressure - Adjust thermostatic cartridge, see "Adjusting"
• Non-return valve defective
Disposal note
Dispose of batteries in accordance with national
regulations.
Remedy
- Clean contacts, see "Electronic cartridge
maintenance"
- Open shut-off valves, isolating valves
- Clean, see "Solenoid valve maintenance"
- Replace, see "Solenoid valve maintenance"
- Attach plug-in connectors, see "Solenoid valve
maintenance"
- Replace, see "Electronic cartridge maintenance"
- Replace, see "Electronic cartridge maintenance"
- Quit cleaning mode, see "Description"
- Replace, see "Solenoid valve maintenance"
- Change detection zone or type of detection with
remote control (Special accessories, Prod.
no.: 36 206)
- Open isolating valves fully
- Check supply lines
- Replace, see "Solenoid valve maintenance"
- Replace, see "Flow straightener maintenance"
- Replace, see "Non-return valve maintenance"
- Replace, see "Thermostatic cartridge
maintenance"
6