- Translation of the original instructions
→
→
→
→
The motor must be used only and always immersed in water.
Please refer to the pump instruction manual for others limitation of use and safety warnings
PREVENTION OF FORESEEABLE MISUSE
→
WARNING!
→
→
→
liquids.
→
5. INSTALLATION
Use suitable means for lifting and transporting the motor: falls, reversals, sudden movements must be avoided.
During handling to maintain appropriate safety distances.
Fix the cables to prevent damage.
Do not expose the cables to the sun.
Do not bend the cables over the minimum permissible bending radius.
Before executing any operation, make sure that the cables are disconnected from the power supply.
PRELIMINARY VERIFICATIONS
Upon receipt of the product must ensure that:
during transport it has not been damaged;
the supply corresponds to order.
Verify that the data shown on the plate, and in particular, power, frequency, voltage, absorbed current,
WARNING!
Verify that the protection and insulation grade indicated on the plate are compatible with the environmen-
Verify that the chemical/physical characteristics of the liquid to be moved correspond to those specified on the
order. In particular:
The liquid must not be explosive or flammable;
WARNING!
The pumped liquid must be compatible with the selected materials;
The sand content should not exceed the allowed limit (usually 50 g / m
The temperature does not exceed the maximum allowed (TAB XX).
Keep the manual for future reference - For more informations visit www.saerelettropompe.com
It is forbidden to use the motor in case of damages or anomalous operations.
Always use the pump with a delivery (flow and head) included in the working diagram.
Motors already used on pump for toxic or harmful liquids or other liquids other than potable water may
not be used for pumping water intended for human consumption.
Don't use the motor in areas frequented by swimmers.
Always use the pump with a delivery (flow and head) included in the working diagram. Do reference to
the name plate and the technical documentation.
Do not operate the pump under the minimum head.
Do not use the pump beyond the limits specified. The use of the pump over those limits can seriously
damage the motor.
Never use the motor in explosive atmospheres, hazardous area or to pump inflammable or dangerous
For the classification of the risky places, refer to local regulations
are compatible with the characteristics of the electric line or current generator available. In particular, the
voltage of the line voltage can have a variance of ± 5% from the nominal voltage value on the plate.
tal conditions.
)
3
33