Release the EM 51 operator with the key provided, as in
fi gure 20, turning the key in a clockwise direction.
Open the up-and-over door completely, measure the
distance L between the support fulcrum on the female
part of the telescopic arm (fi g.21 - 3) and the rotating
shaft of the operator (fi g.21 - 4).
Cut both the female and the male part of the telescopic
arm, to obtain a length L1= L-50 mm; then secure the
female part of the telescopic arm to the fi xed support
(fi g.21 - 3) using the pin (fi g.21 - 5) and the split pin
(fi g.21 - 6).
Position the up-and-over door in the closed position,
insert the male part (fi g.22 - 1) of the telescopic arm in
the female part and secure it to the semi-shaft (fi g.22 -
2) with welding spots (fi g.23 - 3, 4).
Repeat the operation on the other side.
After releasing the operator, lift the up-and-over door by
hand and check that there are no securing problems or
interference with the various moving parts.
At this point, return the door to the closed position and
complete the welding.