Press the casing fi rmly home and engage the teeth in the
housings at the bottom.
•
Fit the screws (fi g.29 - 2, 3).
5.3
DOUBLE OPERATOR
If the weight of the up-and-over garage door is too much for
a single operator, it is necessary to fi t a system consisting of
two operators EM 51 and EM 51 Slave.
The latter has the same technical characteristics and
appearance as the EM 51, except for the absence of the
electronic control unit. In fact the EM 51 Slave only operates
as a driven operator, receiving pulses from the control unit
in the EM 51 operator.
5.3.1 Installation of double operator
Carry out the same preliminary checks as described in
section 4.2 of this manual.
Mount the connections as described above.
Put the two automations to the sides of the frame as described above.
Make the electrical connections following the diagram in Fig. 30.
Warning
•
The connections must be made in compliance with the existing regulations by qualifi ed personnel.
•
Suitable section electric cables must be used.
•
While the connections are being made, the control unit must not be connected to the mains.
6.
EMERGENCY RELEASE
•
Release the operator with the triangular key, turning it in an clockwise direction (fi g.28 - 1) and move the door manually.
•
To block the drive again, turn the triangular key in an anticlockwise direction.
•
Push the door by hand until a mechanical engagement click is heard; this operation is necessary each time the door
is released in manual mode to return to the power-driven mode.Instruct the fi nal customer on how to perform this
operationInstruct the fi nal customer on how to perform this operation
Warning
Instruct carefully the fi nal customer on the use of the system and on how to perform the emergency release
in the event of blackouts.
Fig.30
Fig.29
4
3
- 21 -
Installation
2