Descargar Imprimir esta página

Cautions - Sunoptic Technologies Xenon Pro300 Manual Del Operador

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
Use of the device with accessories or attachments requires the end-user to follow all accessory
or attachment instructions which could affect setup, usage, or functionality.
The fiber optic cables used with this device must be electrically NON-CONDUCTIVE. Such
connections will impair device safety. Cables must be rinsed free of soaking/disinfectant solution
and dry before connecting to turret. Ensure light guide optical surface is clean before connecting
to turret.
This light source can cause permanent eye damage if viewed directly with unprotected eye.
To prevent over-heating, replace lamp with the same type and rating. Read instructions before
replacing the lamp.
Disconnect power supply cord before servicing to avoid electrical shock. Follow instructions when
servicing or changing lamp.
Do not remove cover or reach inside device in order to avoid shock hazard. Servicing must be
performed by qualified personnel.
The device must not be altered in any way. Doing so voids all warranties and statements of
suitability for any purpose.
Avoid dropping or rough handling. Weight and impact of falling device may cause injury.
Use only the power cord supplied with illuminator or medically approved power cords with less
than 200mΩ of ground impedance and less than 16ft (<5m) of length. If unauthorized cables are
used, the device may have increased electromagnetic emissions and/or decreased
electromagnetic immunity which may result in improper operation.
This device meets CISPR 11 Class A limits and is suitable for use in a hospital and industrial
environments. If it is used in a residential environment (for which CISPR 11 class B is normally
required) this equipment might not offer adequate protection to radio-frequency communication
services. The user might need to take mitigation measures, such as relocating or re-orienting the
equipment.
Performance of this device may be affected in proximity of another device and/or equipment
capable of producing high levels of RF emissions. The device should be used no closer than 12
inches (30 cm) to any part of RF equipment including cables. In the event performance of this
device is affected due to high levels of RF emissions, relocation of the suspected device and/or
equipment producing high levels of RF emissions, or the headlight system may reduce or
eliminate the problem.

2.2 Cautions

To prevent improper use or damage to the device, please note the following cautions:
Carefully unpack the device and check if any damage occurred during shipping. If damage is
encountered, refer to the Warranty and Return Policy section of this manual.
Cleaning or sterilization methods not approved be the manufacturer can subject the device to
damage. To reduce this risk, use only approved cleaning and sterilization methods described
herein.
Setup device where connected cables do not become a tripping hazard during use.
Avoid dropping or rough handling. Mechanical shock may cause damage to the device.
NOTE: Device warranty will become void if these warnings or cautions are disregarded.
LIT-263 Sunoptic Technologies
Rev. A
®
Page 5 of 134
(English)

Publicidad

loading

Productos relacionados para Sunoptic Technologies Xenon Pro300

Este manual también es adecuado para:

Dpls-01