Descargar Imprimir esta página

K00424, K00434, K00440, K00450, K00451, K00452 Indigo® Model Power Supply Installation Procedure - Manitowoc LuminIce II Manual De Instalación, Operación Y Mantenimiento

Publicidad

Idiomas disponibles

Idiomas disponibles

Section 2
K00424, K00434, K00440, K00450, K00451,
K00452 INDIGO® MODEL POWER SUPPLY
INSTALLATION PROCEDURE
30" Model Power Supply Mounting
Mount power supply on evaporator
bulkhead above control box. Attach
supplied wire clip and route line voltage
wires through clip.
Install Power
Attach Wire Clip
Supply
Route Line Voltage Wires Through Clip
22" Model Power Supply Mounting
The power supply for the 22" model
mounts behind the control board, below
the access fittings. Route line voltage wires
(black & white) through line voltage Heyco
fitting and attach to L1 and L2 contactor
terminals.
Part Number: 000014110 Rev 01 1/19
1.
Route low voltage wiring (black and
yellow wires) to the LuminIce®. Install
wire clip and route wires close to
evaporator bulkhead to assure harness
is away from any moving parts,
then snap wire harness connectors
together.
2.
Route the line voltage wires (black &
white) through line voltage Heyco
fitting and attach to L1 and L2
contactor terminals.
Route Through Line Voltage Heyco
Attach to Contactor Terminals
Installation
and
11

Publicidad

loading