eNGLISH
Setup and assembly
8.2
Inserting/replacing the clamping shells RPG 3.0
1. Select clamping shells in accordance with the pipe diameter.
2. Unscrew the clamping screw.
3. Compress the clamping shell slightly and insert it into the housing.
4. The Orbitalum logo (1) on the clamping shell must correspond with the
clamping screw (2) (see figure).
5. Tighten the clamping screw (3).
6. Remove the clamping shells takes place in reverse order.
NOTe!
8.3
Inserting/replacing the clamping shells RPG 4.5 and RPG 8.6
8.3.1
Inserting the lower clamping shell
1. Select the clamping shells according to the tube diameter.
2. Move the clamping lever to the open-position.
3. Place the lower clamping shell at the stop bolt (2).
4. Swivel the clamping shell around the stop bolt in the direction of the arrow until the unlock handle locks into place.
58
ORBITALUM TOOLS GmbH D-78224 Singen www.orbitalum.com
The clamping shell is applied correctly when
it has locked in. If the clamping shell does
not lock in, you can readjust by rotating the
clamping shell slightly.
RPG 3.0, RPG 4.5 (S), RPG 8.6
2
1
3
2
[REV. 20210302] OC_RPG_L_BA_790038761_01__INH-02_EN