7.9 PUSH AND PULL INTENSIFIERS

Item numbers in bold refer to the General Assembly drawing and Parts List on pages 25-26.
To remove Intensifi ers 4, 25 and Oil Reservoir 36, disconnect the oil hose using two spanners, (be prepared for oil
spillage from hose/ intensifi er), then remove the hoses (quick release connectors) connecting the intensifi er to the pilot
valve.
Using a spanner, remove the two nuts and associated washers securing the intensifi er to the base plate.
Lift intensifi er clear of cabinet.
Replacement is in reverse order of removal.
CAUTION - Check the tool against daily and weekly servicing
CAUTION - Priming is ALWAYS necessary after the tool has been dismantled and prior to operating.

7.10 PRESSURE REGULATOR AND FILTER ASSEMBLY

To remove the Pressure Regulator and Filter Assembly 45 from the cabinet, disconnect the two Air Hoses 59 and 63 at
the regulator.
Remove the two screws, spacers, washers and nuts securing the regulator to the cabinet.
Remove assembly from the cabinet.
Replacement is in reverse order of removal.
CAUTION -The pressure regulator in the cabinet is set to 5.25 bar.
CAUTION - The pressure regulator must not be adjusted under any circumstances.
CAUTION - The safety valve in the cabinet is set to 5.25 - 5.30 bar.
CAUTION - The safety valve must not be adjusted under any circumstances.

7.11 AIR PRESSURE INDICATOR ASSEMBLY

Item numbers in bold refer to the General Assembly drawing and Parts List on page 17.
To remove the Air Pressure Indicator Assembly 53, remove the air hose from the rear of the gauge.
Remove the clamp from the rear of the gauge and withdraw gauge from front of the cabinet.
Replacement is in reverse order of removal.
After any dismantling/assembling has occurred, the system MUST be primed.

7.12 MOLY LITHIUM GREASE EP 3753 SAFETY DATA

CAUTION - Never use solvents or other harsh chemicals for cleaning the non-metallic parts of the tool. These
chemicals may weaken the materials used in these parts
Grease can be ordered as a single item, the part number is shown in the Service Kit below.
First Aid
SKIN:
As the grease is completely water resistant, it is best removed with an approved emulsifying skin cleaner.
INGESTION:
Ensure the individual drinks 30ml Milk of Magnesia, preferably in a cup of milk.
EYES:
Irritant but not harmful. Irrigate with water and seek medical attention.
Fire
FLASH POINT: Above 220°C.
Not classifi ed as fl ammable.
Suitable extinguishing media: CO2, Halon or water spray if applied by an experienced operator.
Environment
Scrape up for burning or disposal on approved site.

7.13 PROTECTING THE ENVIRONMENT

Assure conformity with applicable disposal regulations. Dispose all waste products at an approved waste facility or site so as
not to expose personnel and the environment to hazards.