Descargar Imprimir esta página

70510-01000 - Bench Mounted Guard Assembly; 70510-01000 - Bench Mounted Guard Pneumatic Circuit - Stanley 70510-01000 Traducción De Instrucciones Originales

Publicidad

Idiomas disponibles

Idiomas disponibles

E N G L I S H
4.2 70510-01000 – BENCH MOUNTED GUARD ASSEMBLY
Refer to illustration opposite (page 11)
From the C-Frame Guard, connect the Black 6mm pneumatic tube (Connected to the 5/2 Roller Valve on the upright
section) to the fitting at the rear of the module (Tail Jaws On). This pipe comes through the side-wall of the main
umbilical.
From the C-Frame Guard, connect the Black 4mm pneumatic tube (Connected to the 5/2 Roller Valve on the upright
section) to the fitting at the middle of the module (Tail Jaws Off ). This pipe comes through the side-wall of the main
umbilical.
From the C-Frame Guard, connect the Blue 6mm pneumatic tube (Connected to the 5/2 Roller Valve on the upright
section) to the left hand fitting on the front face of the intensifier.
From the C-Frame Guard, connect the Blue 4mm pneumatic tube (Connected to the 3/2 Roller Valve on the upright
section) to the right hand fitting on the front face of the intensifier.
From the C-Frame Guard, connect the Green 4mm pneumatic tube (Connected to the 3/2 Roller Valve on the upright
section) to the foot pedal.
Note: Substitute item 56 (7005-1528 Attached to Bench Mounted Guard) banjo connector in place of existing fitting on
the foot pedal.
Fit a hose between the intensifier and the main air supply.
4.3 70510-01000 – BENCH MOUNTED GUARD PNEUMATIC CIRCUIT
Ø 4 BLACK
4(A)
2(B)
3
5
1(P)
GUARD ASSEMBLY
70510-03000
2
3
1
Ø 4 GREEN
10
MODULE
70500-02000
Ø 6 BLACK
2
1
3
Ø 6 BLUE
NON-RETURN
VALVE
FOOT PEDAL
07007-02137
2
1
3
O R I G I N A L I N S T R U C T I O N
INTENSIFIER
07531-02200
Y
X
2
4
1
INTENSIFIER VALVE
Ø 4 BLUE

Publicidad

loading