7. MAINTENANCE

Every 500,000 cycles the tool should be completely dismantled and components should be replaced where worn, damaged
or when recommended. All 'O' rings and seals should be renewed and lubricated with Moly Lithium grease EP 3753 before
assembling.
The employer is responsible for ensuring that tool maintenance instructions are given to the appropriate personnel.
The operator should not be involved in maintenance or repair of the tool unless properly trained.
The airline must be disconnected before any servicing or dismantling is attempted, unless specifically instructed otherwise.
It is recommended that any dismantling operation be carried out in clean conditions.
The potentially dangerous substances that could have deposited on the machine as a result of work processes must be
removed before maintenance.

7.1 DISMANTLING THE 70510

Separating the Module from the Assembly
Remove the nose jaw equipment from the Modular
Head Assembly.
Remove the Modular Head Assembly & Tool
Mounting Block from the guard, by using the
appropriate Allen Key*.
Remove the Mounting Block from the Module by
using the appropriate Spanner*.
Disconnect nipple from self-closing coupling at the
intensifier.
Remove the 6mm Tube by depressing the collar on
the swivel elbow fitting. Using a Spanner* remove
swivel elbow from module.
Remove the 4mm Tube by depressing the collar on
the swivel elbow fitting. Using a Spanner* remove
swivel elbow from module.
Using a spanner* remove the hydraulic hose
assembly, compact elbow, hydraulic adaptor and
dowty seals from the module.
*
Refers to items included in the service kit, see page
16.
18
IMPORTANT
Safety Instructions appear on page 4-5.