Descargar Imprimir esta página

Putting In Service; Preliminary Operations; Air Supply - Stanley 74290 Manual De Instrucciones Y Servicio

Ocultar thumbs Ver también para 74290:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 112
O R I G I N A L I N S T R U C T I O N

3. PUTTING IN SERVICE

IMPORTANT
- READ THE SAFETY RULES ON PAGE 4 - 6 CAREFULLY BEFORE PUTTING INTO SERVICE.
Select relevant size nose equipment and install.
Connect the placing tool to the air supply. Test pull and return cycles by depressing and releasing the trigger 40.
Set the tool for desired stroke/pressure.
CAUTION: Correct supply pressure is important for proper function of the installation tool. Personal injury or damage
to equipment may occur without correct pressures. The supply pressure must not exceed that listed in the placing tool
specification.

3.1 PRELIMINARY OPERATIONS

Every day, before using the tool, carry out the operations described in section "LUBRICATION".
Before connecting the tool to the air supply, blow compressed air through the feed pipe, in order to eliminate any trace of
condensation water or foreign matter.
LUBRICATION: Prior to connecting the air hoses, pour a small quantity of light hydraulic oil into the air admission fitting

3.2 AIR SUPPLY

All tools are operated with compressed air at an optimum pressure of 5 and 7 Bar. We recommend the use of pressure
regulators and automatic oiling/filtering systems on the main air supply. These should be fitted within 3 metres of the tool
(see diagram below) to ensure maximum tool life and minimum tool maintenance.
Air supply hoses should have a minimum working effective pressure rating of 150% of the maximum pressure produced
in the system or 10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and
should be armoured where operating conditions may result in hoses being damaged. All air hoses MUST have a minimum
bore diameter of 6.4 millimetres or 1/4 inch.
We recommend to operate the tool at the minimum pressure necessary to obtain the requested hole, to consume less air
and the maximum tool life is ensured.
Read servicing daily details page 13.
(USEDDURINGMAINTENANCE OF
FILTER/REGULATOR OR
LUBRICATIONUNITS)
MAXIMUM
MAXIMUM
3
3
LUBRICATOR
Fig. 2
STOP COCK
8
PRESSURE REGULATOR AND
FILTER (DRAIN
DAILY)
E N G L I S H
TAKEOFFPOINT
FROMMAINSUPPLY
MAIN SUPPLY
DRAIN POINT
9

Publicidad

loading