PPE FEATURES
I.IV.
When maintaining and cleaning the machine,
the following PPE is required:
Gloves
To protect the user from all machine
parts that become hot or come in con-
tact with food (filter holders, filters, etc.).
Only perform the maintenance and
cleaning operations indicated in this
manual.
Any maintenance and cleaning operations
not indicated in this document can only be
performed by a specialised and authorised
Technician.
All maintenance operations can only be car-
ried out once:
• the power supply has been disconnected.
• the water supply has been shut off.
• the gas supply system has been shut off.
• the machine has fully cooled down.
If a malfunction cannot be resolved, turn the
machine off and call out the Technician. Do
not attempt any repairs.
The appliance must be descaled by the Tech-
nician in order to prevent materials that are
hazardous for food use from being released.
EMERGENCY SITUATIONS
I.V.
Should an emergency situation occur as a result
of a machine malfunction, adopt the measures
provided for in the emergency plan posted in
the premises and in any case, proceed to imme-
diately carry out the actions based on the type
of problem.
USER Manual
SHORT CIRCUIT FIRE
In the event of a fire caused by the machine's
electrical system malfunctioning, adopt the fol-
lowing behaviours:
• Disconnect the machine from the power
mains via the main switch.
• Call the fire and rescue service.
• Get everyone a safe distance away from
the premises.
• Extinguish the flames using a CO
extinguisher.
GAS LEAK
In the event of a fire caused by the machine's
system malfunctioning, adopt the following be-
haviours:
• Shut off the gas supply by closing the
valve upstream of the machine.
• Get everyone a safe distance away from
the premises.
• Ventilate the premises.
• Call the technician that installed the ma-
chine.
• If necessary, call the fire and rescue ser-
vice.
GAS LEAK FIRE
In the event of a fire caused by the machine's
gas system malfunctioning, adopt the follow-
ing behaviours:
• Shut off the gas supply by closing the
valve upstream of the machine.
• Disconnect the machine from the power
mains via the main switch.
• Call the fire and rescue service.
• Get everyone a safe distance away from
the premises.
• Extinguish the flames using a CO
extinguisher.
fire
2
fire
2