TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
180
TCA
30
300
t. l ight
output
1
240
ti e
OP. D IST.
7
99
SLOUD
CL. D IST.
7
99
SLOUD
PARTIAL
10
99
OPENING
1
99
out prog 1
1
99
out prog 2
1
99
OP. F ORCE
1
99
CLS. F ORCE
rev. d is.
0
200
space
25
99
OP SPEED
25
99
CL SPEED
ainte-
0
250
nance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Automatic
TCA
Closing Time
STEP-BY-STEP
Step-by-step
movement
OVE NT
Movement on
sw
ov
endstop
Pre-alarm
PRE-ALAR
22-
ARGO BT A 20-35
Default
Personal
Definition
Automatic closing
40
time [s]
Lighting time of the
90
courtesy light [s]
Activation time of
10
the timed output [s] Activation length of timed radio channel output in seconds
Slow-down distance
7
during opening [%]
Slow-down distance
7
during closing [%]
20
Partial opening [%]
Output 1, pro-
50
grammable
in height
Output 2, pro-
50
grammable
in height
Leaf force during
75
opening [%]
Leaf force during
75
closing [%]
Reverse
0
disabling space
99
Opening speed [%}
45
Closing speed [%]
Programming num-
ber of operations
0
for maintenance
threshold
[in hundreds]
Cross
out
Default
setting
used
0
Logic not enabled
0
1
Switches automatic closing on
Inputs configured as Start E, Start I, Ped oper-
0
ate with 4-step logic.
0
Inputs configured as Start E, Start I, Ped oper-
1
ate with 3-step logic. Pulse during closing
reverses movement.
0
Logic not active
3
Causes the movement to be reversed when it stops on the closing limit switch
1-10
(10 = Greater movement)
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
ENGLISH
Waiting time before automatic closing.
Lighting time of the courtesy light [s] Activation time of the courtesy light on the board
Slow-down distance for motor(s) during opening, given as a percentage of total travel. WARNING: Once
the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total travel. WARNING: Once
the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation of PED pedestrian
command.
The output set as AUX=17 (see the AUX outputs Configuration table) gets activated when the
door exceeds the opening percentage set in this parameter (1% = door closed, 99% = door open).
The output set as AUX=18 (see the AUX outputs Configuration table) gets activated when the
door exceeds the opening percentage set in this parameter (1% = door closed, 99% = door open).
Force exerted by leaf/leaves during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm
is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force delivered, beyond the
force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is
generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary (**).
Disables obstacle/curb detection near the limit stop in closing
0 = no disabling 200 = disabling Maximum
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary.
Percentage of maximum speed that can be reached by motor(s) during opening. WARNING: Once
the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing. WARNING: Once
the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Allows you to set a number of operations after which the need for maintenance will be reported
on the AUX output configured as Maintenance or Flashing Light and Maintenance .
Optional extras
DURING CLOSING
DURING OPENING
AFTER STOP
Description
step-by-step mov.
3 STEP
CLOSED
OPENS
OPEN
CLOSES
STOP + TCA
OPENS
4 STEP
OPENS
STOPS
CLOSES
STOP + TCA
OPENS