Descargar Imprimir esta página

Publicidad

Enlaces rápidos

INSTALLATION GUIDE
RAZR Modular
2'x4' and 4'x4'
Light Fixtures for Racks
GLOBAL
THANK YOU FOR CHOOSING FLUENCE!
Please confirm that all hardware and accessories received are correct for your
RAZR Modular application by referring to the RAZR Modular System Wiring
Guide before you begin the installation.
1. CAUTIONS AND WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 Fertigation Warning Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 General Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Important Safety Precautions & Explanation of Symbols . . . . . . . . . . . . . 6
1.4 Cultivation Best Practices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5 General Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. DIMENSIONS AND WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Assembled 2'x4' and 4'x4' Light Fixtures . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. PREPARATION FOR SYSTEM INSTALLATION . . . . . . . . . . . . . . . . . . . 8
3.1 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.2 Installation Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Installation Steps Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4. INSTALLATION STEPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.1 Step 1 - Assemble the Light Fixtures . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Step 2 - Mount the Light Fixtures to the Rack According to the Lighting Design . 12
4.3 Step 3 - Install the DC Splitter and Manifold Cables . . . . . . . . . . . . . . . 14
4.4 Step 4 - Mount the Power Supply to the Rack . . . . . . . . . . . . . . . . . . . 16
4.5 Step 5 - Connect the DC Manifold Cable(s) to the Power Supply . . . . . . . . . 20
4.6 Step 6 - Connect the AC Power Cable to the Power Supply . . . . . . . . . . . . 20
4.7 Step 7 - (Optional) Connect the DC Dimming Cable to the Power Supply and then to
a Dimming Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.8 Step 8 - Power and Test the System . . . . . . . . . . . . . . . . . . . . . . . . 22
5. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6. PRODUCT GUARANTEE & WARRANTY . . . . . . . . . . . . . . . . . . . . . . 24
© Copyright 2023 Fluence Bioengineering 032023 | Subject to change without notice

Publicidad

loading

Resumen de contenidos para Osram FLUENCE RAZR Modular GLOBAL

  • Página 1 INSTALLATION GUIDE RAZR Modular 2’x4’ and 4’x4’ Light Fixtures for Racks GLOBAL THANK YOU FOR CHOOSING FLUENCE! Please confirm that all hardware and accessories received are correct for your RAZR Modular application by referring to the RAZR Modular System Wiring Guide before you begin the installation.
  • Página 2 1. CAUTIONS AND WARNINGS 1.1 FERTIGATION WARNING STATEMENT CAUTION: Allowing repeated and/or CONTINUED contact with fertigation and/or mineralized water to the light fixture may result in reduced product life or failure, VOIDING warranty of the product. PRECAUCIÓN: Permitir el contacto repetido y/o continuo con fertirrigación y/o agua mineralizada al dispositivo de iluminación puede resultar en una reducción de la vida útil del producto o en fallas, anulando la garantía del producto.
  • Página 3 1. CAUTIONS AND WARNINGS 1.2 GENERAL CAUTIONS AND WARNINGS CALIFORNIA PROPOSITION 65 WARNING WARNING CAUTION CAUTION CAUTION WARNING: This product contains Risk of electrical shock. LED and heatsink surfaces To reduce the risk of To prevent eye damage, chemicals known to the State of California to cause cancer and birth To reduce the possibility may be hot.
  • Página 4 ADVERTÊNCIA (PT) 1. CAUTIONS AND WARNINGS Risco de choque elétrico. Para reduzir a possibilidade de ferimentos graves, tome sempre as devidas precauções e desligue a luminária antes de a mover ou limpar. A luminária e a fonte de alimentação suojaamattomiin LED-valoi. LED-valojen ja jäähdytyslevyjen pinnat voivat olla kuumia. Anna niiden jäähtyä são classificadas como UL 1598 (Adequado para Locais Húmidos), mas não são projetadas para serem riittävän kauan ennen käsittelyä.
  • Página 5 1. CAUTIONS AND WARNINGS aramutes veszelyevel szemben, a SELV erteket nem haladja meg a feszultseg. PL Produkt chroni przed porażeniem prądem elektrycznym dzięki obwodowi bardzo niskiego napięcia (SELV), nie przekraczającemu napięcia powyżej SELV. SK Produkt chrani pred zasiahnutim elektrickym prudom použitim ochranneho nizke- ho napatia (SELV), nedosahuje sa napatie prekračujuce SELV.
  • Página 6 1. CAUTIONS AND WARNINGS 1.5. GENERAL CARE 1.3. IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS RAZR Modular lighting systems are passively cooled with zero moving components. They are designed for harsh environments and years of • Please read this manual thoroughly before attempting to install or reliable performance.
  • Página 7 2. DIMENSIONS AND WEIGHT 2.1 ASSEMBLED 2’ X 4’ AND 4’ X 4’ FIXTURES Assembled Light Fixture Bar Spacing Length Width Height Weight Region 8.0” Right Angle 18.9” 2.9 lb 2’ x 4’ 3-Bar 203.2 mm 480 mm 1.3 kg DC Splitter 47.05”...
  • Página 8 3. PREPARATION FOR SYSTEM INSTALLATION 3.1 BEFORE YOU BEGIN... IMPORTANT: Please be sure to match the EXACT light bar quantity per power supply to the BAR COUNT on Power Supply SKU label for proper system performance. A differed bar count from SKU label would result in INCORRECT LIGHT OUTPUT from light bars. For best system performance, only use supplied DC cables or contact FLUENCE for alternative recommendations.
  • Página 9 3. PREPARATION FOR SYSTEM INSTALLATION 3.2 INSTALLATION PLANNING A little planning before beginning the installation can pay big dividends in reduced installation time and labor cost. 1. Review and measure the rack tier spacing to plan the routing of all cables. 2.
  • Página 10 3. PREPARATION FOR SYSTEM INSTALLATION 3.3 INSTALLATION STEPS OVERVIEW IMPORTANT: Read each installation step completely for important notes regarding proper installation before you begin. It is recommended to install RAZR Modular in the following sequence of steps: IMPORTANTE: Antes de comenzar, lea cada paso de instalación completamente para obtener notas importantes sobre la instalación adecuada.
  • Página 11 4. INSTALLATION STEPS 4.1 - STEP 1: ASSEMBLE THE LIGHT FIXTURES • Dedicate a cleared and clean work space for assembling the light fixtures. • An additional step of connecting the DC splitter cables to the light fixtures as part of the fixture assembly process may reduce work time required on the ladder or scissor lift.
  • Página 12 4. INSTALLATION STEPS 4.2 - STEP 2: MOUNT THE LIGHT FIXTURES TO THE RACK ACCORDING TO THE LIGHTING DESIGN Light Fixture Wire Hanger Options Three lengths of wire hangers are available that are ideal for specific rack types. Any of the lengths though can be used that best fit your specific application.
  • Página 13 4. INSTALLATION STEPS Assembled Light Fixture Mounting Point Measurements 2’x4’ 3-Bar Fixture 2’x4‘ 4-Bar Fixture 4’x4’ 6-Bar Fixture 4’x4’ 8-Bar Fixture IMPORTANT: • Two persons are recommended for the mounting of light fixtures to ensure safety. • Avoid touching the LED’s while mounting the light fixtures. IMPORTANTE: •...
  • Página 14 4. INSTALLATION STEPS 4.3 - STEP 3: INSTALL THE DC SPLITTER AND MANIFOLD CABLES DC Splitter Cables Straight Connector Right-Angle Connector All DC splitter cables use a push-lock type M16 2-pin connector to connect the cable to the light fixture LED bars to a port on the DC manifold cables.
  • Página 15 4. INSTALLATION STEPS Baker’s Rack, 2’x4’ 3-Bar Fixture, 4-Fixture Array (12 Bars) Installation Steps Connect the plugs of the splitter end of the DC splitter cable to each light bar on the first fixture and the last fixture in the array for 2-foot wide fixtures, or the furthest set of light bars in 4-foot wide fixtures (see the examples below).
  • Página 16 4. INSTALLATION STEPS 4.4 - STEP 4: MOUNT THE POWER SUPPLY TO THE RACK IMPORTANT: Ensure a minimum of 2 inches (5.08 cm) of clearance above the power supply between the ceiling or hard surface, and/or heat sources, to ensure sufficient air flow for proper cooling. IMPORTANTE: Asegúrese de que haya un mínimo de 5,08 cm (2 pulgadas) de espacio libre por encima de la fuente de alimentación entre el techo o la superficie firme y / o las fuentes de calor, para garantizar suficiente flujo de aire para un enfriamiento adecuado.
  • Página 17 4. INSTALLATION STEPS Power Supply Surface Mount Kit Installation Instructions Bracket Positions Inward Outward The mounting brackets can be installed outward or inward. If installed inward, it may be necessary to first mount the brackets to the surface. Bracket Installation Place one bracket behind the power supply end plate and align the screw holes.
  • Página 18 4. INSTALLATION STEPS Power Supply Wire Hanger Mounting Kits Unistrut Hanger Kit (AMV2-10120-20) Suitable for Unistrut up to 1 ” (45 mm) wide. Pipe Hanger Kit (AMV2-10121-20) Ideal for mounting under pipes up to 1 ¾” (45 mm) in diameter. Square Hanger Kit (AMV2-10119-20) Suitable for trusses or channel up to 2 ¾”...
  • Página 19 4. INSTALLATION STEPS Power Supply Wire Hanger Installation Instructions Unistrut, Pipe, or Square Hanger Kit Take (2) mounting brackets and hang a bracket over the support structure. Locate the holes for brackets on the narrow side of PSU power supply, hold up the power supply under the support structure under it.
  • Página 20 4. INSTALLATION STEPS 4.5 - STEP 5: CONNECT THE DC MANIFOLD CABLE(S) TO THE POWER SUPPLY IMPORTANT: Please be sure to match the EXACT light bar quantity per power supply to the BAR COUNT on Power Supply SKU label for proper system performance.
  • Página 21 4. INSTALLATION STEPS IMPORTANT: Please be sure to match the EXACT light bar quantity per power supply to the BAR COUNT on Power Supply SKU label for proper system performance. A differed bar count from SKU label would result in INCORRECT LIGHT OUTPUT from light bars. IMPORTANTE: Asegúrese de aparear la cantidad EXACTA de barras de luz por la fuente de alimentación con el CONTADOR DE BARRAS en la etiqueta SKU de la fuente de alimentación para un rendimiento adecuado del sistema.
  • Página 22 4. INSTALLATION STEPS 4.7 - STEP 7: (OPTIONAL) CONNECT THE DC DIMMING CABLE TO THE POWER SUPPLY AND THEN TO A DIMMING CONTROLLER The DC dimming cable uses a coaxial type A-code M12 3-pin connector to connect the cable to the power supply. To install the DC dimming cable: Remove the dust cap from the power supply dimming port and let it hang by the chain.
  • Página 23 5. TROUBLESHOOTING POTENTIAL CAUSE RESOLUTION CONDITION Check the power supply label first to identify how Some installed LED light bars are many light bars should be connected to it. Add or The quantity of light bars per power supply are not at different brightness levels even remove light bars to the correct quantity for the correctly matched.
  • Página 24 6. OUR PRODUCT GUARANTEE & WARRANTY Every Fluence Lighting system is engineered and built by Fluence Bioengineering using state-of-the-art robotics and hand craftsmanship. All Fluence Lighting systems are guaranteed against manufacturing defects for five years from date of purchase. Fluence lighting systems comply with applicable standards and are intended to be used with Fluence power supplies, cables and mounting hardware.