Descargar Imprimir esta página

Ferroli OMNIA M 3.2 22T Manual De Instalación Y Del Propietario página 103

Publicidad

Idiomas disponibles

Idiomas disponibles

OMNIA M 3.2
9.2.2 Hydraulic system diagram
Coding
Assembly unit
1
Air purge valve
2
Expansion vessel
3
Circulation pump
4
Pressure relief valve
5
Manometer
6
Flow switch
7
Refrigerant gas connection
8
Refrigerant liquid connection
9
Plate heat exchanger
10
Water outlet connection
11
Water inlet connection
12.1
Electrical heating tape
12.2
Electrical heating tape
/
Temperature sensors
9.3 Electronic control box
Back view
Filter
board
(PCB
C)
Note:The picture is for reference only, please refer to the actual product.
22T÷30T
Remaining air in the water circuit will be automatically removes air from the
water circuit.
Balances water system pressure. (Expansion vessel volume: 8L)
Circulates water in the water circuit.
Prevents excessive water pressure by opening at 3 bar and discharging
water from the water circuit.
Provides water circuit pressure readout.
Detects water flow rate to protect compressor and water pump in the event
of insufficient water flow.
Transfer heat from the refrigerant to the water.
For heating plate heat exchanger
For heating connection pipe of expansion vessel
Four temperature sensors determine the water and refrigerant temperature
at various points in the water circuit. (T2B; T2; Tw out; Tw in)
Inverter module
(PCB A)
Cod. 3QE47660 - Rev. 00 - 02/2022
Explaination
/
/
/
/
Front view
EN
Main control
board of unit
(PCB B)
Main control
board of
hydraulic module