9.3.3 Main control board of unit
Coding
Assembly unit
1
Power supply port for PCB B (CN41)
2
Port for IC programming (CN11)
3
Port for pressure sensor (CN6)
4
Port for sunction temp.sensor (CN5)
5
Port for discharge temp.sensor (CN8)
Port for outdoor ambient temp, sensor and condenser
6
temp.sensor (CN9)
7
Port for low pressure switch and quick check (CN29)
Port for communication with hydro-box control board
8
(CN24)
9
Port for communication with PCB C (CN4)
10
DIP switch (S5,S6)
11
Port for communication with Power Meter (CN26)
12
Port for electrical expansion value (CN22)
13
Port for fan 31OVDC power supply (CN53)
106
EN
OMNIA M 3.2
Coding
Power supply port for hydro-box control boaid
14
(CN21)
15
Port for other temp.sensor (CN35)
16
Port for communication XYE (CN28)
17
Port for 4-way value (CN18)
18
Port for eletric heating tape1 (CN10)
19
Port for eletric heating tape2 (CN7)
20
Port for communication D1D2E (CN37)
Port for high pressure switch and quick check
21
(CN31)
22
Port for fan 15VDC power supply (CN30)
23
Port for fan (CN 107/109)
24
Port for communication with PCB A (CN36)
25
Port for GND (CN38)
26
Port for SV (CN20/27)
Cod. 3QE47660 - Rev. 00 - 02/2022