OMNIA M 3.2
10.7.16 Setting parameters
The parameters related to this chapter are shown in the table below.
Order
Code
number
1.1
DHW MODE
Enable or disable the DHW mode:0=NON,1=YES
1.2
DISINFECT
Enable or disable the disinfect mode:0=NON,1=YES
Enable or disable the DHW priority
1.3
DHW PRIORITY
mode:0=NON,1=YES
Enable or disable the DHW pump
1.4
PUMP_D
mode:0=NON,1=YES
DHW PRIORITY
Enable or disable the DHW priority time
1.5
TIME SET
set:0=NON,1=YES
The temperature difference for starting the heat
1.6
dT5_ON
pump
The difference value between Twout and T5 in DHW
1.7
dT1S5
mode
The maximum ambient temperature that the heat
1.8
T4DHWMAX
pump can operate at for domestic water heating
The minimum ambient temperature that the heat
1.9
T4DHWMN
pump can operate for domestic water heating
t_INTERVAI_
the start time interval of the compressor in DHW
1.10
DHW
mode.
the temperature difference between T5 and T5S that
1.11
dT5_TBH_OFF
turns the booster heater off.
the highest outdoor temperature the TBH can
1.12
T4_TBH_ON
operate.
the time that the compressor has run before starting
1.13
t_TBH_DELAY
the booster heater
the target temperature of water in the domestic hot
1.14
T5S_DISINFECT
water tank in the DISINFECT function.
the time that the highest temperature of water in the
1.15
t_DI_HIGHTEMP.
domestic hot water tank in the DISNFECT function
will last
1.16
t_DI_MAX
the maximum time that disinfection will last
t_DHWHP_
he operation time for the space heating/cooling
1.17
RESTRICT
operation.
the maximum continuous working period of the heat
1.18
t_DHWHP_MAX
pump in DHW PRIORITY mode.
friable or disable the DHW pump run as timed
D PUMP TIME
1.19
and keeps running for PUMP RUNNING
RUN
TIMEO=NON,1=YES
PUMP D
the certain time that the DHW pump will keep
1.20
RUNNING TIME
running for
Enable or disable the DHW pump operate when
D PUMP
1.21
the unit is in disinfect mode and T5≥T5S_DI-
DISINFECT
2:0=NON,1=YES
2.1
COOL MODE
friable or disable the cooling mode:0=NON,1=YES
The refresh time of climate related curves for
2.2
t_T4_FRESH_C
cooling mode
The highest ambient operation temperature for
2.3
T4CMAX
cooling mode
the lowest ambient operating temperature for
2.4
T4CMIN
cooling mode
the temperature difference for starting the heat
2.5
dT1SC
pump (T1)
the temperature difference for starting the heat
2.6
dTSC
pump (Ta)
2.7
t_INTERVAL_C
the start time interval of the compressor in COOL mode
The setting temperature 1 of climate related curves
2.8
T1SetC1
for cooling mode.
The setting temperature 2 of climate related curves
2.9
T1SetC2
for cooling mode.
The ambient temperature 1 of climate related curves
2.10
T4C1
for cooling mode.
The ambient temperature 1 of climate related curves
2.11
T4C2
for cooling mode.
ZONE1
The type of zone1 end for cooling mode: 0=FCU (fan
2.12
C-EMISSION
coil unit), 1=RAD. (radiator), 2=FLH (floor heating)
22T÷30T
State
Cod. 3QE47660 - Rev. 00 - 02/2022
Default
Mnumum Maximum
1
0
1
1
0
1
1
0
1
0
0
1
0
0
1
10
1
30
10
5
40
43
35
43
-10
-25
30
5
5
30
5
0
10
5
-5
50
30
0
240
65
60
70
15
5
60
210
90
300
30
10
600
90
10
600
1
0
1
5
5
120
1
0
1
1
0
1
0.5
0.5
6
52
35
52
10
-5
25
5
2
10
2
1
10
5
5
5
10
5
25
16
5
25
35
-5
46
25
-5
46
0
0
2
EN
Setting
Unit
interval
1
/
1
/
1
/
1
/
1
/
1
°C
1
°C
1
°C
1
°C
1
MIN
1
°C
1
°C
5
MIN
1
°C
5
MIN
5
MIN
5
MIN
5
MIN
1
/
1
MN
1
/
1
/
0.5
hours
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
/
135