INDEX
7.4 VOLTAGE CHECK
Check that the voltage of the system corresponds to the mains voltage. If not so, make the appropriate changes to the
electric system and change the voltage of the motor.
7.5 CONNECTING UP TO THE MAINS
Versione trifase: 400V 50Hz 380V 60Hz
sezione cavo >= 4mmq 3poli + terra P=11KW I=20A
Versione trifase: 230V 50Hz 220V 60Hz
sezione cavo >= 6mmq 3poli + terra P=11KW I=32A
Controllare inoltre che a monte si trovi un dispositivo di interruzione automatica contro le sovracorrenti dotato di salvavita da 30mA.
7.6 CONNECTIONS
- Pass the power cable inside the box through the cable grip and connect the wires to the terminal board (see wiring diagram).
First Installation.
Warning: Lift platforms could be misaligned due to packing.
Take platforms to ground (downstroke limit) as described in chapt. 8.5 of the manual.
Any work done on electrical parts, including minor jobs, must be carried out by specialised engineers.
MOTOR CONNECTION
CONNECTING THE TRANSFORMER
The electrical system is preset to work at the voltage shown on the serial number plate.
FUSES
TENSIONE MAGGIORE
HIGHER VOLTAGE
400V 50Hz
380-480V 60Hz
220-277V 60Hz
230V
24V –– 40
0
–– 9
0
–– 15
230 –– 16
400
230V
32A
SPMA32 - SPMA35
TENSIONE MINORE
LOWER VOLTAGE
230V 50Hz
400V
24V –– 40
0
–– 9
0
–– 15
230
400 –– 16
400V
20A
0473-M004-0
EN_23