Information settings & measurement method:
1. Load the batteries or press the button of power, Bi-bi sound accompanies the operation and
button pressing.
2. When the buzzer makes the sound of BI, the product enters into the information set-up status of
the fat testing, ('Guest' fl ashes):
3. At that time, please press 'up' or 'down' key to change the current fat-testing information groups;
shows the display picture when press 'up' for once; the product can install ten groups of fat-testing
materials, i.e. one group of visitors and nine groups of members; If button 'set' is pressed, then we
enter the guest information setup screen, as shown in following step 4 to step 7; the setup method
for the other nine groups are the same;
4. When 'group' fl ashes, press SET button to enter into height setup, then the height amount fl ashes.
Its initial value is 160.0cm; during the setup, every press of 'up' or 'down' will increase or decrease
the height value by 0.5cm; Continuous pressing up or down will fasten the setup. You can set up
the height value by above method; and the valid value range will be:100-199.5cm
5. After setting up the height, press SET key to enter into weight value setup the weight value
fl ashes, and the initial value is 60.0kg; during the setup, every press of 'up' or 'down' will increase
or decrease the weight value by 0.2kg; Continuous pressing up or down will fasten the setup. You
can set up the weight value by above method; and the valid value range will be:10.0-199.8kg.
8