CONTENTS
1
GENERAL PRESCRIPTIONS
1.1
Safety prescriptions
1.2
Installation prescriptions
1.3
Operating prescriptions
2
2.1
2.2
3
PRODUCT TECHNICAL SPECIFICATIONS
4
4.1
4.2
Operating limits
4.3
4.3.1 Installation
4.3.2 Installation of limit stops and switches
4.3.3 Operator manual release
5
5.1
5.1.2 Terminals for control of accessories
6
7
PRODUCT MAINTENANCE
8
9
10
1 GENERAL PRESCRIPTIONS
1.1 SAFETY PRESCRIPTIONS
This installation manual is addressed exclusively
to professionally skilled personnel. Read all
the instructions carefully before starting the
installation procedures. Any operations that are
not expressly set down in these instructions
are to be considered prohibited; improper use
may result in damage to the product and place
persons and property at risk. The manufacturer
declines all liability for the failure to observe
best practices in door construction and for any
possible deformation that may occur during
use of the product. Store this manual in a safe
place for future reference. The design and
construction of the devices of which model
RAMPART is composed and this manual are in
full compliance with statutory legislation.
In consideration of potential hazards that
may arise during the installation and use of
RAMPART, the installation procedures must be
carried out in full compliance with the applicable
laws, standards and regulations; namely:
1.2 INSTALLATION PRESCRIPTIONS
• Before starting the installation procedures
make sure you have any additional devices
and materials that may be required to complete
the automation system with RAMPART in
consideration of the specific application.
16
COMUNELLO ®Copyright 2018 - All rights reserved
• The automation system must not be used
until the door has been made safe.
• Dispose of packaging materials in compliance
with local regulations.
1.3 OPERATING PRESCRIPTIONS
• No modifications can be made to any part of
the product unless specified in this manual.
Unauthorized modification of the product is
likely to lead to malfunctions. The manufacturer
declines all liability for damage caused by
unauthorized modifications.
• The parts of the automation system must
never be immersed in water or other liquids.
During the installation procedures ensure that
no liquids penetrate inside the control unit or
other open devices.
• If liquids penetrate any parts of the automation
system disconnect the electrical power
supply immediately and consult Comunello
technical service; the use of RAMPART in
such conditions may give rise to potentially
hazardous situations.
• Keep all parts of the RAMPART automation
system away from heat sources and open
flames; exposure to heat or flames may
damage the devices and cause faults, fire, or
hazardous situations.
• When the equipment remains unused for a
long time, remove the optional battery and
store it in a dry place to avoid the risk of
leakage of harmful substances.
• Connect the control unit exclusively to an
electric power supply line equipped with an
efficient protective earth conductor.
• Any operations that require the housing of
RAMPART to be opened must be performed
with the control unit disconnected from the
electrical power supply; if the disconnect
device is not clearly visible from where you are
working, attach a warning notice to the effect:
"WARNING - MAINTENANCE IN PROGRESS".
• In the case of tripping of circuit breakers or
blowing of fuses, find the fault and remedy it
before resetting the circuit breaker or changing
the fuse.
• If the fault cannot be remedied using the
information given in this manual, consult
technical service.
• The device can't be used by children
younger than 8 years of age and by people
with reduced physical, sensory or mental
capabilities, or without experience or the
required knowledge if not under surveillance
or after having received instructions about the
safe use of the device and the inherent risks
in it. Children should not play with the device.
Cleaning and maintenance should not be
carried out by children without surveillance.
• Children can't play with the commands of
the automatism. Remote controls should be