Installation
According to the law, all gas equipment must be installed by competent persons in accordance with
current legislation on safety of installations and rules of use.
Make sure that you comply with the law.
Room ventilation
The air required for combustion is taken from the room air and the gases emitted are given off directly
into the room. For safe operation of your product, good room ventilation is a prerequisite. If there is no
window or space to be used for room ventilation, additional ventilation must be installed. However, if the
room has a door to the outside, it is not necessary to make ventilation openings.
Gas conversion
Exercise caution in operations and adjustments when converting from one gas to another.
This work must be carried out by a qualified technician.
Before starting, turn off the gas and electrical power to the appliance.
1. Replace the burner nozzle
Remove the pot support, burner cap and flame spreader.
Unscrew the injector with a 7 mm spanner and replace it with the injector stipula-
ted for the new gas flow. After replacement, it is advisable to tighten the injectors in
place.
2. Adjust the minimum flame level
Turn the knob to the minimum.
Remove the knob inside the spanner shaft and tighten the small screw in the centre
of the spanner shaft. The correct setting is obtained when the flame is approximately
3-4 mm long.
Control knob
Adjustement screw
Seal ring
* For butane/propane gas, the screw adjustment must be correctly
tightened.
correctly tightened.
* Replace the key in the knob.
* Make sure that the flame does not go out quickly when going from
maximum to minimum.
Make sure that the flame does not go out quickly when switching from
maximum to minimum.
Repeat this process for each of the gas connections.
39
English