S5: SET-UP/parameters key
Permits access to the SET-UP and welding parameter values.
When pressed at switch-on, it permits access to the set-up
parameters while the software version appears on D1.
If pressed after the end of the welder switch-on procedure, it
selects in sequence the welding parameters presented in the
graph G1 with value shown by D1 and variable with E1.
Tu Slope-up time
l
Welding current
lb
Basic current in pulsed and medium frequency welding
Tp Peak time in pulsed and medium frequency welding
Tb Basic time in pulsed and medium frequency welding
Td Slope-down time
lf
Final current
Pg Post-gas time
l2
Second welding current in BILEVEL
When in MEDIUM FREQUENCY operation,
the leds Tp and Tb come on simultaneously
and the pulse frequency value appears on
the display D1.
Parameter
um
Pre-gas time
s
Initial current
%
Slope-up time tu
s
Welding curr. l
A
Back curr. lb
A
Pulse time tp
s
Frequency tp & tb
Hz
Back time tb
s
Slope-down time td
s
Final current lf
A
Post-gas time
s
Hot-Start
%
Arc-force
%
l max in external mode
A
l min in external mode
A
l2 in BILEVEL
A
4.2 Rear control panel (Fig. 2)
*
l1: Ignition switch
Controls electric ignition of welder.
It has two positions: "O" off and "l" on.
WARNING
*
With l1 set to the position "l" on, the welder is opera-
tional and voltage is present between the positive (+)
and negative sockets (-) on the electrode. In TIG the wel-
der requires the pedal or torch button start for voltage
to be present between the sockets (+) and (-).
*
When the welder is connected to the mains, even with
l1 set to the "O" position some of the internal parts will
be live. Carefully follow the warnings given in this
manual.
Notes
Can be entered only from set-up
Percentage of welding current, only set-up
Can be entered from front panel
Can be entered from front panel
Only pulsed, adjustable from front panel
Only pulsed slow, adjustable from front panel
Only in fastpulse, adjustable from front panel
Only pulsed slow, adjustable from front panel
Adjustable from front panel
Adjustable from front panel
Adjustable from front panel
MMA, can be entered only from set-up
MMA, can be entered only from set-up
Adjustable from front panel and from set-up
Can be entered only from set-up
Adjustable from front panel
*
Set-up parameters
When S5 is pressed after switch-on, the set-up menu is acces-
sed (confirmed by a central "0" on the display D1) while the
software version appears on D1. Via E1 the set-up line is
varied, via S5 the required line is confirmed, via E1 the value
is varied, via S5 the value is confirmed and so on.
0 Quit and save
1 Initial current as a percentage with respect to welding cur-
rent
2 Pre-gas time
3 HOT-START percentage
4 ARC-FORCE percentage
6 Min current value in TIG EXT
7 Max current value in TIG EXT welding
9 Reset of all parameters
14 Pulsed TIG basic l setting mode (0=in amps, 1=percenta-
ge of peak l)(default=0)
23 TIMER mode setting
(23 = 0: 2-stage mode, 23 ≠ 0: welding time)
99 Reset of all parameters
If we enter lines "9" and "99" and press S5, all the
set-up parameters will go to the factory-set values.
To quit set-up and save the set values, return to
line 0 and press S5.
*
1: Power supply cable
*
2: Gas fitting
min
max
predef.
0.0
25.0
0.0
2
200
0.0
10.0
0.0
6
240
100
6
240
0.02
2.00
0.24
20
500
100
0.02
2.00
0.24
0.0
10.0
0.0
6
240
0.0
25.0
5.0
0
100
0
100
6
240
240
6
240
6
240
Fig.2
50
6
8
80
30
6
50
17