Descargar Imprimir esta página

Dometic Frigo DC VAK Instrucciones De Montaje página 11

Ocultar thumbs Ver también para Frigo DC VAK:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Frigo DC VAK
➤ Attach the DC unit to the base frame with the 4 x M8 x 25 Allen screws,
4 x M8 Ø24 washers and 4 x M8 stop nuts included in the scope of delivery
of the DC unit (fig. 5).
➤ Connect the negative lead (Ø35 mm
(included in the scope of delivery of the DC unit) with the connection block
in the DC unit (fig. 6 1).
➤ Connect the positive lead (Ø35 mm
with the high-power relay in the DC unit (fig. 6 2).
➤ Protect the connections on the high-power relay and connection block with
a protective wax or similar.
➤ Position the compressor connection cable to the cable attachment at the out-
put of the DC unit (fig. 6 3).
➤ Attach the compressor connection cable with the cable tie included in the
scope of delivery of the DC unit (fig. 6 3).
➤ Secure the connection cable in the area of the compressor (fig. 6 4).
➤ Secure the cover of the relay block with a cable tie (fig. 6 5).
➤ Reattach the cover (fig. 7).
➤ Position the base frame with the DC unit under the vehicle using a suitable lift-
ing device(fig. 8).
➤ Insert the base frame into the 4 holders and secure it at the rear with 2 x
M8 x 20 bolts, 4 x M8 Ø24 washers and 2 x M8 stop nuts and at the front
with 2 x M8 x 25 bolts, 4 x M8 Ø24 washers and 2 x M8 stop nuts (fig. 8).
➤ Make sure that all screw connections and nuts are tightened to the correct
tightening torques.
➤ Bend the heat shield on the exhaust silencer back to its original position.
A
NOTICE!
Make sure that after installing the Frigo DC VAK, there is no interference
between the components you have attached and the parts on the vehicle.
EN
2
) of the compressor connection cable
2
) of the compressor connection cable
Installation
9

Publicidad

loading