Troubleshooting
EN
If the appliance is not working properly, the screen display will show an error message.
Please refer to the troubleshooting table to find your solution.
Error Icon
Possible Cause
Insufficient water in Clean
Water Tank
Used Water Tank full
Brush roller stuck
Brush roller not installed
Blocked tube
Troubleshooting
Possible Cause
Code
E1-E7
Error
H1-H6
Battery
H7
overheating
19
19
Solution
Fill the Clean Water Tank.
Empty the Used Water Tank.
Clean the brush roller with the
provided cleaning brush.
Install the brush roller.
Check whether the filter is clogged.
Alternatively, clean the tube and
the dirt sensor.
Solution
Restart the appliance for troubleshooting.
If the problem persists, please contact
customer service.
Wait until the battery's temperature returns
normal.
Specifications
Wet and Dry Vacuum Floor Washer
Model
HHV3
Rated Voltage
21.6 V
Used Water Tank
700 mL
Capacity
Rated Power
300 W
Power Adapter
Model
YLS0251B-E260090
100-240 V~ 50/60 Hz
Input
0.8 A Max
Output
26 V
0.9 A
Charging Time
Approx. 5 hours
Charging Voltage
26 V
Clean Water Tank
900 mL
Capacity
No-load Power
0.08 W
Consumption
Average Active
87.28%
Efficiency
Efficiency at Low
79.74%
Load (10%)
EN