Additional adjustment, if necessary, may be
attained by loosening the four shaft collar set
screws, the two rock shaft crank clamp
screws, Fig. 20, and the feed lifting clamp
screw, Fig. 19. Move the complete assembly
to required position and tighten screws.
Lengthwise Setting
The feed dog should clear the ends of the feed
slots in the throat plate equally at both ends of
the feed travel. To adjust, set the feed for the
desired stitch length. Loosen the two rock
shaft crank clamp screws, Fig. 20. Move the
feed rocker forward or backward until the
correct positioning is attained. Then tighten
the two clamp screws.
Technical Manual & Parts Book
Ajustes adicionales, si es necesario, pueden ser
conseguidos aflojando los cuatro tornillos de
fijación del collarete del eje, los dos tornillos de
la abrazadera del codo de manivela del eje
movible, Fig.20, y el tornillo de la abrazadera de
alimentación y elevación. Mueva el ensamblaje
completo a la posición requerida y apriete los
tornillos.
Ajuste Longitudinal
Los dientes de arrastre deben despejar el final de
las ranuras de alimentación de la plancha de
aguja en ambos extremos en el trayecto de la
alimentación. Para ajustar, fije la alimentación
por el largo deseado de la puntada. Afloje los
dos tornillos de la abrazadera del codo de
manivela del eje movible, Fig.20. Mueva el
alimentador móvil hacia adelante o hacia atrás
hasta que la correcta posición sea obtenida.
Luego apriete los dos tornillos de la abrazadera.
49
1345-3C