SYSTEM LAYOUT
TECHNICAL DATA
Opening/closure time
Maximum torque
Power supply
Absorption in stand-by
Maximum absorption
Accessories power supply
Service
Operating temperature
Protection rating
Type and frequency of use
Weight
620
UP 2.0
1,5÷8 s / 90°
45 Nm
full range 100 ÷ 240 Vac 50/60 Hz
3 W
70 W
24 Vdc = 1 A max
100%
-15°C ÷ +50°C
(batteries: -10°C ÷ +50°C)
IP 31
Continuous operation = 100%
8,5 Kg
125
Using UP 2.0 to move a very heavy door could reduce the performance indicated.
Complying with the working temperature range declared in the technical data
would allow you to obtain the use frequency value in the table.
Data have been detected in standard use conditions and cannot be guaranteed for
each individual case.
Each automatic input has variable elements, such as: friction, balancing,
environmental conditions which can substantially change both the working
duration and quality of the automatic input or part of its components.
The technician is responsable for implementing the safety coefficients on each
particular installation.
Indicazioni di utilizzo
Recommended dimensions
Dimensional limits
Use not allowed
0
50
0
500
1000
1500
mm
IDENTIFICATION OF THE COMPONENTS
1. Command control unit UP 2.0
2. Gearmotor 24Vdc with encoder
3. Reducer unit
4. Extended range power supply unit 100-240Vac 50/60 Hz
5. Side head
6. Aluminium frame
7. Arm coupling bushing
8. Aluminium cover
3
100
150
200
250
kg
G
B