The power supply cable can be connected to an electrical socket (not supplied by us), prepared near the automation head.
If an electrical socket is not present near the automation, connect to the electrical mains as follows: perforate the aluminium box at the top, protect passage of the power
supply cable using cable glands (not supplied by us) to eliminate sharp edges which could damage the power cable, and connect the cable to the electricity supply.
Connection to the electrical power supply, in the section outside automation, must takes place via an independent duct and separate from the connections to the command
and safety devices.
ELECTRONIC CONTROL TERMINAL BOARDS
When you connect the safety devices, remove the jumpers of the corresponding terminals.
Terminals J20 (grey)
Description
L / H /+24V / -24 V
BUS connection (not used)
Terminal J3 (green)
Description
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the following chapters.
TS
N.B. For devices without testing, connect the N.C. contact to the TS/OS terminals.
N.C. safety contact in opening side B (right hand side of automation view). When the door is opening, opening the contact causes
TS /OS
slowing of the door in the last 500 mm (the safety function of the OS terminal can be modified using the advanced parameters menu).
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS/OS jumper.
+24V / - 24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminals J10 (black)
Description
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the following chapters.
TS
N.B. For devices without testing, connect the N.C. contact to the TS/CS terminals.
N.C. safety contact in opening side A (left hand side of automation view). When the door is opening, opening the contact causes slowing
TS /CS
of the door in the last 500 mm (the safety function of the CS terminal can be modified using the advanced parameters menu).
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS/CS jumper.
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminal J5 (green)
Description
OP-E
N.O. opening contact side B (external side of automation view).
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Morsetti J9 (nero)
Descrizione
OP-I
N.O. opening contact side A (internal side of automation view).
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminals J17 (green)
Description
S
Rotary selector signal ACG9475B (with key ACG9474B)
+24V / -24V
Rotary selector power supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminals J4 (grey)
Description
USB
PP
S
+24V
-24V
I3
IO2
IO1
+24V
-24V
+LK
-LK
J1
- MOT +
ENC
ENTER
ESC
11
G
B