G
B
SIO1
Setting input/output IO1
SIO2
Setting input/output SIO2
SI3
Setting input SI3
Warnings
SIGN
Activation of output contact SIO1/SIO2 (SIO1/
SIO2 set on SIGN)
Operating mode to activate on low/high
SAM1
transition of contact IO1/IO2 (with SIO1/SIO2
set on SAM)
Operating mode to activate on high/low
SAM2
transition of contact IO1/IO2 (with SIO1/SIO2
set on SAM)
Automatic closure time in the event of Key
TAKO
Open (KO) input enabling
ALARMS
Code
Description
W001
Encoder fault
W002
Motor short circuit
W003
Motor control error
W004
Current reading circuits fault
W010
Movement inverted
W011
Stroke too long.
W012
Stroke too short
W013
Beyond stop
W014
Motor absent/faulty
W100
User program not correct, Absent
EVENTS
Code
Description
W128
No mains power supply
W129
No battery
W130
Battery flat
W140
OS safety test failed
W142
CS safety test failed
NO
Disabled
WARN
Alarm status signalling
SERV
Number of manoeuvres reached for maintenance signalling
SIGN
Warning. Select the type of signal using the SIGN parameter
BELL
Buzzer activation in input/activation of door
RSET
Automation reset contact
EMER
Emergency open contact (NC)
KO
Key Open Contact (priority Open command)
VOPN
Virtual open contact
KC
Key Close Contact (priority Close command)
Step-step opening (open impulse/lose impulse). During opening by steps, automatic
STEP
closure is disabled.
STOP
Immediate stop command
SAM
Select operating mode from signal level SIO1
Same as SIO1
See SIO1
Same input
See SIO1 limited to input functions: RSET, EMER, KO, VOPN, KC, STEP, STOP, SAM.
functions as SIO1
CLOS
Closed door warning
LAMP
Flashing/light (door in motion)
AIR
Air knife
OPEN
Open door warning
CLOS
Door closed
1D
One-directional
1DPA
Partial one-directional
OPEN
Door open
AUTO
Automatic/day mode
See 'SAM1'
NO
Closure time equal to TAC (Automatic closure time)
1 - 30
Differentiated automatic closure time [s]
Notes
Encoder faulty The automation blocks
A motor short circuit has been detected. The control blocks movement for 1.5s then tries to power the motor again
Error on motor control circuit. The automation blocks
Reading the motor currents is not correct. The automation blocks
Movement detected of direction contrary to that set. The automation blocks.
During the acquisition phase, a stroke was detected over the maximum permitted. The automation blocks
During the acquisition phase, a stroke was detected under the minimum permitted. The automation blocks
During operation, a stroke was detected longer than that acquired. The automation blocks
Detected in approx. 3s, if the motor was detached or faulty (no current absorption)
Software upgrade unsuccessful or corrupted. Switch off and back on the board (with the USB pen inserted) to restart
the upgrade procedure
Notes
Enabled if an operating mode is set which includes battery presence
Insufficient battery voltage detected
The door stays open
The door stays open
18