MEM MENU
ID
Description
FSET
Back to factory settings
FW
Fw upgrade on board
SIN
Settings loading from USB
SOUT
Settings saving on USB key
ADV MENU (Advanced)
ID
Description
SCEX
Space for safe bypass during closure
SOEX
Space for safe bypass during opening
SSOP
Behaviour on safety activation opening
ELLK
Electric lock operating mode
LKPW
Electric lock power supply voltage
TALK
Electric lock activation advance time
TRLK
Electric lock activation time
LKSH
Electric lock coupling thrust in closure
PIPP
Leaf open check enabled
PUCL
Thrust force with door closed
HOLD
Maintenance force with door open
TS
Safety sensors test enabling
PUGO
Push and Go
MOT
Motor configuration disabled
Values
NO/YES
Name of upgrade
files
*(NOMS)
NO/YES
*(NOMS)
NO/YES
*(NOMS)
Values
Notes
Safety not bypassed
0
Interval in degrees within which the safety is bypassed (angle measured compared to
10 - 50
closure stop)
Safety not bypassed
0
Interval in degrees within which the safety is bypassed (angle measured compared to
10 - 50
opening stop)
On activation of the opening safety, the door stops, then the automatic closure time
CLOS
expires, also with the safety active
On activation of the opening safety, the door stops, then the safety disables and opening
OPEN
continues. The door remains still for the entire time the safety is active.
NO
Electric lock not present
LOCK
Standard electric lock, theft-proof
12
12Vdc
24
24Vdc
0,5s - 5s
Use if the electric lock takes a certain time to disengage and allow door movement.
0,5s - 5s
Electric lock power supply time
NO
No coupling thrust
MIN
MED
3 force levels applied
MAX
YES = Check enabled, on each opening, the open position is checked by pushing on the
NO/YES
leaf stop
NO
No thrust
MIN
MED
3 force levels applied
MAX
NO
No thrust
MIN
MED
3 maximum strength levels applicable to keep the door in the open measurement
MAX
NO/YES
YES = Sensors test enabled
NO/YES
YES = Manual movement of the door from closed door causes opening
OC
Windings open - Manual opening with little friction
Short-circuited motor windings
SC
Manual opening of the door with greater resistance
17
Notes
Select YES and press ENTER, after 2s the writing "FSET" re-appears,
confirming the operation. Resetting the default settings causes automatic
resetting of the board, which therefore on subsequent movement will
execute an acquisition manoeuvre
Select the Firmware version to upgrade from those available. The upgrade
files should be inserted in the path RIBDS/SLIDING/FW/
*If NOMS appears, the USB pen is not detected or absent
Select YES and keep ENTER pressed until the writing SAVE appears.
*If NOMS appears, the USB pen is not detected or absent
Select YES and keep ENTER pressed until the writing SAVE appears.
*If NOMS appears, the USB pen is not detected or absent