G
MENÙ
B
The UP 2.0 control board is equipped with 5 buttons and 4 alphanumerical displays to set all the necessary adjustments.
Operation of the 5 buttons is showed in the table
Buttons
Description
PP (OP)
OPEN button Executes the OPEN command equivalent to KO contact.
ENTER
Selection button, each time it is pressed you enter the selected parameter.
Saving button, pressing for 1 second you "SAVE" the selected value.
ESC
Escape button, each time it is pressed you exit the selected parameter or from the menu.
h
Scroll button, each time it is pressed, you select a menu item or increase the value of the selected item.
i
Scroll button, each time it is pressed, you select a menu item or reduce the value of the selected item
MENU LIST
- -ON-
basic parameters
- INFO
board information
- MEM
memory management
- ADV
advanced parameters
-ON- MENU
ID
Description
OPEN
Opening direction selection
VOP
Opening speed
VCL
Closure speed
TAC
Automatic closure time
PUSH
Automation thrust force
BTMD
Battery operating mode
ARM
Arm type
LEAF
Door weight
RAMP
Acceleration time
INFO MENU
ID
Description
Display of possible anomalies and operating information
SHOW
on the display
VER
Fw version
CYCL
Number of executed manoeuvres
SERV
Maintenance signalling setting
LOG
Saving the board log
WARN
List of the last 10 warnings
L
H
+24V
+24V
- 24V
TS
OS
+24V
- 24V
TS
CS
+24V
-24V
OP-E
+24V
-24V
OP-I
+24V
-24V
Values
Notes
<> −>
Opening to right
<−
Opening to left
15°/70°
degrees/s
15°/70°
degrees/s
NO
NO = automatic closure disabled
1 - 30
[s]
1 - 10
1 = min, 10 = max
NO
Battery not considered
CONT
Continuous operation
EMER
Opens in emergency
PUSH
Articulated arm
PULL
Sliding arm
MIN
Light door
MAX
Medium/heavy weight door
100 - 2000
100 = Maximum acceleration [ms]
Values
Notes
CONT
Display of active contacts of the terminal boards + warning
WARN
Warning only
XXXX
XXXX = firmware version
0 - 9999
Number of executed manoeuvres in thousands: 1 = 1000 manoeuvres
NO = signalling disabled
NO
Number of manoeuvres after the maintenance warning on the display of
1 - 9999
the control unit (in thousands) or setting SIO1/SIO2 signalling
Select YES and press ENTER until the writing SAVE appears. The log file (text file)
NO/YES
will be saved in
*(NOMS)
MYONEDS/SLIDING/LOG/
*If NOMS appears, the USB pen is not detected or absent
The warnings are put in the order of the most recent to the oldest (0.xxx
... 9.yyy)
16
USB
PP
S
+24V
-24V
I3
IO2
IO1
+24V
-24V
+LK
-LK
J1
- MOT +
ENC
ENTER
ESC