ELECTRICAL CONNECTIONS
B
L
H
+24V
- 24V
TS
OS
+24V
- 24V
TS
CS
+24V
-24V
OP-E
+24V
-24V
OP-I
+24V
-24V
Ref.
Code
1
2
3
4
5
GENERAL ELECTRICAL SAFETY WARNINGS
The installation, electrical connections and adjustments must be carried out in compliance with good practice and in compliance with standards in force.
Before connecting the electrical power supply, ensure the plate data correspond to those of the electrical distribution mains. On the power supply mains, install an omnipolar
switch/sectioning device with an opening distance of the contacts equal or over 3mm. This switch must be protected from unauthorised activations.
Check upstream of the electrical system that there is an adequate differential switch and an overcurrent safety device.
Connect the automation to an efficient earthing system installed as indicated by safety standards in force.
During installation, maintenance and repair operations, remove the power supply before opening the casing to switch on the electrical parts.
The electronic parts must be handled using anti-static, conductive wrist straps connected to the ground.
RIB S.r.l. cannot be held in any way liable if components are installed which are incompatible for safety purposes and for good operation.
For possible repair or replacement of products, only original spare parts must be used.
The plate data are found on the label positioned in front.
ELECTRICAL POWER SUPPLY CONNECTION
Use a power cable for connection to the power supply mains.
3
2
USB
ENC
PP
ENTER
S
+24V
-24V
ESC
I3
IO2
IO1
+24V
-24V
+LK
-LK
Terminals
Description
PWR
Electricity mains control unit.
UP 2.0 electronic control
MOT
Direct current gearmotor
ENC
Angular sensor
Battery group ACG9632
BAT
LK
Electric lock
4
4
1
5
12/24 Vdc
I max 1A
10
N
100÷240 Vac
L
50/60Hz