UP 2.0 INSTALLATION with sliding arm for inward openings
Fitting UP 2.0 with sliding arm (AA12052B)
1 - Check the wall is straight and smooth.
2 - Drill, respecting the measurements indicated in Fig. A.
3 - Insert the plugs (supplied) or thread M8.
4 - In a stable manner fasten the automation to the wall tightening the M8 screws.
Fasten the sliding guide on the door as indicated in the figures, respecting the measurements indicated and cutting the excess part of the guide if the door is narrow.
Fig. A
14 mm from door hinge
X* = ESTÁNDAR + ACG9485 (73 mm)
electric cable entry
X* = 47mm (STANDARD)
= Drill a hole Ø6,5 and thread it in order to use M8 screws - Drill a hole Ø14 if you prefer to use Fischer dowels.
5
14 mm from door hinge
electric cable entry
X*
X* = STANDARD + ACG9485 (102 mm)
2
1
G
B