6.2
The pump
6.3
The motor
6.4
Protective functions and alarmes
7
Installation and electrical con-
nection
Installation and operating instructions • Medana PE3 • Ed.02/2023-04
1
Figure 5
1.
Stop valve
Figure 7
1.
Lagging
2.
Wooden plate
3.
Ground
4.
Waterway
5.
Cover the exposed piping
Multistage horizontal centrifugal, Shaft sealing with mechanical seal.
Dry running with water cooling jacket, single-phase, 2-pole motor, 50Hz: capacitor in the
terminal box, motor protection switch with automatic reset.
Protection rating: IP X4 (with installed male electrical connector)
Insulation class: B130
Frequency
Speed in RPM at 3_High speed
Speed in RPM at 2 middle speed
Speed in RPM at 1 Low speed
Voltage
•
Frozen protection: Green LED fhashes
When water inside the pump reaches freezing temperatures, it makes pump operated
automatically and prevent damage from frost by a temperature sensor.
•
Dry running protection (Low water protection): Red LED flashes
The pump automatically stops after 10seconds when driving with no water inside the
pump. Automatically return to operation after 10 minutes.(Continuous dry running 10
seconds/10 minutes repeat when dry running continues.
Or the pump automatically stops when the temperature sensor is over 65 degree and
automatically return to running when temperature is less than 65 degree (for the first
time, it takes about 10 minutes operating and 20 minutes stop. After that, operating 1
minute / stop 5 minutes repeat).
It is possible to occur the dry running protection at maximum flow point. Thus, if the dry
running protection is operated, please adjust the discharge valve to increase the pres-
sure.
•
Operation disconnection and overload protection: Red LED flahses
The pumps stops when the temperature inside the pump exceeds a certain level, auto-
matically return to operation when the temperature inside the pump reaches a certain
level below.
•
Leakage operation protection: Red LED flashes
The pumps stops when the temperature inside the pump exceeds a certain level, auto-
matically return to operation when the temperature inside the pump reaches a certain
level below.
•
Over-Pressure protection: Red LED 3 times and Green LED 3 times flashes alternately
The pumps stop when the inside pump pressue exceeds 5kgf/㎠, automatically return to
operation when the inside pump pressure becomes less than 5kgf/㎠.
All installation and electrical connection work must be carried out solely by authorised
and qualified personnel, in accordance with applicable regulations.
en
1
50Hz
~ 2900
~ 2500
-
1~ 220-230V (±10%)
11