CAUTION: WHEN THIS HEATER IS CONNECTED TO A FLUE PIPE, THE FLUE PIPE SHALL
TERMINATE IN A VERTICAL SECTION AT LEAST TWO FEET LONG AND SUFFICIENT DRAFT
SHALL BE CREATED TO ASSURE SAFE AND PROPER OPERATION OF THE HEATER. WHERE
BACK DRAFTS MAY OCCUR, A VERTICAL CAP SHOULD BE USED ON THE EXIT FROM THE
FLUE PIPE. HORIZONTAL RUNS OF THE FLUE PIPE SHOULD HAVE A RISE 1 IN 10 AWAY
FROM THE HEATER .
RESET/RESTART – MANUAL (ON/OFF SWITCH)
When the appliance locks out, move the ON/OFF switch to position OFF and then to position ON again to
restart the appliance (see also "Troubleshooting").
AIR PRESSURE SWITCH
The heater is equipped with an air pressure switch that controls the airflow pressure. In the event of over-
heating the pressure switch shuts the heater down. If this occurs, detect and eliminate the cause of over-
heating before using the heater again. Have the heater inspected by a qualified technician if required. To
reset, let the unit cool unit down and then restart it as described above.
SHUT DOWN
Move switch to "OFF" (O) position. The fan continues to rotate for about 2 minutes to cool the combustion
chamber. Then the appliance automatically shuts down.
NEVER DISCONNECT THE SUPPLY PLUG TO STOP THE HEATER WHILE IN OPERATION. THE
BIG AMOUNT OF HEAT PRODUCED COULD DAMAGE THE COMPONENTS: ALLOW COOLING
SEQUENCE TO TAKE PLACE.