[d] SWITCHING TO AUTOMATIC DISPENSING MODE
1) Hold the bottom of the operation panel unit and pull the front handle toward you to unlock.
2) Pull down the operation panel unit until it stops to cover up the beer tap lever. The dispense
lamp comes on.
To prevent injury, do not hold the cross-marked part but hold the curved surface at the front
side when pulling down the operation panel unit.
To avoid damage, do not pull down the operation panel unit by force without unlocking the
handle.
7. SOLD OUT SENSOR
When the beer keg becomes empty, the unit automatically detects the condition and stops the
dispensing operation. The sold out lamp lights up, and the dispense button becomes unavailable.
The sold out sensor is factory set to "0: Setting A (mainly beer)".
In the manual dispensing mode, the unit will not stop dispensing even if the sold out lamp lights up. Be careful with the keg
level while dispensing beer.
When the sold out lamp lights up, replace the beer keg. See "3. [d] REPLACING BEER KEG" and "4. [b] LEADING BEER TO
TAP".
8. END OF DISPENSING OPERATION
1) Close the beer circuit.
Rotary type: Turn the keg coupler handle counterclockwise until it stops.
Vertical type: Unlock and lift the keg coupler handle all the way up.
When the keg coupler on the keg is closed, gas may stay inside the beer circuit. To
prevent excessive foaming or improper dispensing actions, lead beer into the beer
circuit until gas comes out of the beer tap before starting operation on the following
day. See "4. [b] LEADING BEER TO TAP".
2) Flush the beer circuit according to "III. 2. BEER CIRCUIT (DAILY)".
3) Turn the regulator adjust dial to set the pressure to "0" (MPa).
4) Close the main valve of the CO2 gas cylinder by turning it clockwise.
Note: To prevent too much CO2 gas entering the beer keg, always close the main valve of the CO2 gas cylinder at the end of
dispensing operation.
5) Wipe off moisture from the end of the beer tap nozzles. Clean and attach the nozzle caps (accessory).
Note: Always attach the accessory nozzle caps at the end of dispensing operation or during periods of non-use
to prevent entrance of insects or dirt into the beer tap nozzles.
9. SHUT DOWN
[a] SHUT DOWN
1) Check that the keg coupler is closed. See "8. END OF DISPENSING OPERATION".
Note: If the keg coupler is open, the floor can be wet in the event of beer leakage.
CAUTION
IMPORTANT
IMPORTANT
19
ENGLISH
Operation Panel Unit
Lever
Beer Tap
Hold here
Handle
Keg Coupler Handle
Rotary Type
Vertical Type
Nozzle Cap