OPERATING INSTRUCTIONS
en
54
O P E R A T I N G I N S T R U C T I O N S | WTM12L MultiMode
Adjust the sensing range and distance to the object and background as well as the
remission capability of the object according to the corresponding diagram (x = sensing
range, y = minimum distance between set sensing range and background (white, 90%))
Remission factor: 6% = black 1, 18% = gray 2, 90% = white 3 (relative to standard
white as per DIN 5033). We recommend making the adjustments using an object with a
low remission factor.
MultiMode 1/3/4/5:
Minimum distance in mm (y) between the set sensing
range and white background (90 % remission)
y
120
(4.72)
90
(3.54)
60
(2.36)
6%/90%
30
1
(1.18)
0
0
250
(9.84)
Recommended sensing range for
the best performance
Figure 13: WTM12L-xxxxx1xx, MultiMode 1/3/4/5
1
80/90
400
2
80/90
3
80/90
0
250
(9.84)
(19.69)
A
Recommended sensing range for the best performance
Figure 14: WTM12L-xxxxx1xx, MultiMode 1/3/4/5
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Visibility range
D
Setting range switching threshold for background suppression
E
Sensing range indicator
F
Teach-Turn adjustment
Blue
Recommended sensing range for the best performance
18%/90%
2
90%/90%
3 3
x
500
750
1,000
(19.69)
(29.53)
(39.37)
Distance in mm (inch)
700
850
500
750
1,000
(29.53)
(39.37)
Distance in mm (inch)
D
BluePilot
E
F
C
B
Example:
Safe suppression of the background
White background (90 %)
x
Black object (6 % remission)
Set sensing range x = 250 mm
Needed minimum distance to white
background y = 6 mm
8027716.1HYU/2023/04/25 | SICK
Subject to change without notice
y