Descargar Imprimir esta página

SICK WTM12L MultiMode Serie Instrucciones De Uso página 62

Ocultar thumbs Ver también para WTM12L MultiMode Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
OPERATING INSTRUCTIONS
6.4.5
Setting in MultiMode 2:
en
6.4.6
Setting in MultiMode M:
6.5
Additional functions
62
O P E R A T I N G I N S T R U C T I O N S | WTM12L MultiMode
Sensor teach-in with foreground suppression
1.
Position object in the desired position and press the control element for 1-3 sec‐
onds until the yellow LED flashes.
x
Background
The sensor is adjusted and ready for operation.
Table 10: Teach result without object
Object present
Please refer to the enclosed "IO-Link photoelectric sensors" operating instructions for
information about adjusting the IO-Link sensing range.
Mode M (Manual/Measurement) can only be selected and set using IO-Link.
The blue LED for mode M lights up when the device is used in measuring mode or when
additional settings are made that differ from standard modes 1-6.
The sensor should be aligned according to the respective basic mode. If in measuring
mode, the sensor is aligned with the object to be measured without having to observe
additional boundary conditions such as a preferred direction.
NOTE
How to output a distance value is also shown in a video:
Please refer to the enclosed "IO-Link photoelectric sensors" operating instructions for
information about adjusting the IO-Link sensing range.
IO-Link
The sensor can be used in standard I/O mode (SIO) or IO-Link mode (IOL). All auto‐
mation functions and other parameter settings are effective in IO-Link mode and in
standard I/O mode. Output of binary switching signals in standard I/O mode via pin
4 / black wire and via pin 2 / white wire.
3
4
5
6
2
1
M
8027716.1HYU/2023/04/25 | SICK
Subject to change without notice

Publicidad

loading

Este manual también es adecuado para: