4
5
34
-
12.1,
3
ADJUSTING
PRESSURE.
2
You can adjust the pressure and hence the temperature of the water in the boiler by
means of the pressure switch viewing it on the pressure gauge (1).
Remove the cup heating plate (2) as described in the paragraph on installation.
Act on the screw (3) of the pressure switch turning it CLOCKWISE to decrease
the pressure and ANTICLOCKWISE to increase it.
12.2,
ADJUSTING THE PUMP PRESSURE.
1
You can adjust the pump pressure checking it on the pressure gauge (4).
Remove the cup heating plate (2) as described in the paragraph on installation.
Act on the screw (5) of the pump turning it CLOCKWISE to decrease the
pressure and ANTICLOCKWISE to increase it.
W ARNING: These operations must be carried out by a qualified
technician operating with extreme care.