AL 100 Charger
The AL 100 charger has no fan and
waits for the battery to cool down before
starting the charging process. The
battery is cooled by heat transfer to the
ambient air.
End of Charge
The charger switches itself off
automatically when the battery is fully
charged:
LEDs on the battery go off.
–
The LED on the charger goes off.
–
The charger's fan is switched off (if
–
charger is so equipped)
Remove the fully charged battery from
the charger.
MSA 160 C, MSA 200 C
LEDs on battery
Four LEDs show the battery's state of
charge and any problems that occur on
the battery or power tool.
1
Press button (1) to activate the
N
display – the display goes off
automatically after 5 seconds.
The LEDs can glow or flash green or
red.
LED glows continuously green.
LED flashes green.
LED glows continuously red.
LED flashes red.
During Charging Process
The LEDs glow continuously or flash to
indicate the progress of charge.
A green flashing LED indicates the
capacity that is currently being charged.
0 - 20 %
20 - 40 %
40 - 60 %
60 - 80 %
80 - 100 %
The light emitting diodes on the battery
go off automatically when the charge
process is completed.
If the LEDs on the battery flash or glow
red – see "If the red LEDs glow
continuously / flash".
English