"OPEN CIRCUIT"
"Chl. error"
4.5- Operation times
It may be useful to see the operation times for regular maintenance operations.
From the main screen, press both buttons at the same time.
4.6- Electrolysis cell life
The electrolysis cells from our units are designed to reach a lifespan of 10.000
hours (10K models) and 5.000 hours (5k models). However, this lifespan is
directly related with the quality of the water and specially with the correct use
of the equipment. Please, read the following suggestions in order to guarantee
that your cell reaches the specified lifespan.
a) Salt concentration:
swimming pool has a sufficient salt concentration, otherwise the cell will
degrade prematurely if you keep it working permanently in low salt
conditions. It is important to add salt when the unit shows the "lack of
salt" indication.
b) Low temperature operation: Don't keep the system work in low
water temperature conditions (under 15ºC). As an alternative, there are
some hibernation products that keeps the water in good conditions in
winter time. If you still want to use it in low water conditions, please
Manual EVO v.4
Cell
is
incorrectly
connected.
Cell
is
damaged
completely worn down.
Swimming pool water with
very
low
concentration.
Chlorine
probe
incorrectly connected or
damaged
Water contains very low
redox potential.
The equipment does not
have a probe and is in
"automatic mode".
It is very important that the water of your
Check the cell connection and
ensure
that
connection terminals are in good
condition.
or
Check the condition of the cell
electrodes, and replace it if any
damage is observed.
Ensure that the water has salt
salt
and that it is dissolved.
is
Check the cabling of the probe
and the probe itself. Check 5.1.
It can work in manual mode if
necessary.
Leave the equipment to chlorate
in manual mode for at least 2
hours.
Check the chemical balance of
the water. (appendix 1)
Install a Redox or Free Chlorine
probe,
or
configure
mode.
cables
and
"manual"
105 / 166