4.4- Warning messages and alarms (EVO)
In the event of abnormal operation, the EVO series equipment will display an
alarm message on the 4th line of the screen, together with an acoustic
warning. The alarms shutdown the equipment until the problem is solved.
Similarly, it will display a warning also in the 4th line, but without an acoustic
signal or shutting down the equipment. In this case, the equipment can
continue operating, although you are informed that corrective action should be
taken.
4.4.1- Warnings
Message:
"LACK OF SALT"
"EXCESS SALT"
"CLEANING"
"TEMPERATURE".
Manual EVO v.4
Swimming pool water with
very low salt concentration.
Causes:
Lack of salt in the water.
Incrustations or objects in
the electrolysis cell causing
lack of current.
The electrolysis cell is worn.
Excess salt in the water.
Incrustations or objects in
the electrolysis cell causing
excess current.
The chlorinator is in the
self-cleaning process. The
process lasts 5 minutes
The ambient temperature is
>40º
The
radiator
fins
obstructed or are not in a
vertical position.
Ensure that the water has
salt and that it is dissolved.
Action required:
Add salt to the swimming pool.
Clean the cell.
Replace the electrolysis cell with
a new one.
No action required if excess is
not very significant.
Clean the cell.
None.
Try and place the equipment in
another position where it is not
over 40º or perform forced
ventilation.
equipment to rest for a few
minutes.
Consult section number
4. Installation
are
Place the equipment so that air
is circulated for correct cooling.
Leave
the