3-position lever switch, or selector switch
L
BPJE2
BPJDE2
(BPSE2)
- Switch the main switch on.
- Switch the panel on.
- The valve is operated by means of the lever switch.
- The lever will not stay in positions 'L' and 'R' . The lever will always
jump back to the middle position 'C' .
- After using the bow thruster switch the panel off.
- Switch the main switch off when leaving the ship.
4
Installation instructions
These installation instructions give guidelines for fitting the VETUS
hydraulic bow thrusters 'BOW55HMD' , 'BOW95HMD' , 'BOW160HMD' ,
'BOW230HMD' , 'BOW310HM'D, 'BOWH410' and 'BOWH550' .
This installation instruction explains only that part of the installation
that differs from the installation instruction going with the bow thrus-
ters '55 kgf' model '55 kgf' ('BOW55HMD'), '95 kgf' ('BOW95HMD'),
'160 kgf' ('BOW160HMD'), '230 kgf' ('BOW230HMD'), '310 kgf'
('BOW310HMD'), '410 kgf' ('BOWH410') and '550 kgf' ('BOWH550')
So consult for the installation of the entire hydraulic bow thruster
also the relevant bow thruster instruction.
Installation and user manual Hydraulic bow thruster 55, 95, 160, 230, 310, 410, 550 kgf
C
R
5-position lever switch
2L
1L
BPJ5
BPJSTH5
BPJ5D
- Switch the main switch on.
- Switch the panel on.
- The valve is operated by means of the lever switch.
- In positions '1L' and '1R' the bow thruster works at approximately
half the thrust (depending on the load-sensing pressure set).
- In positions '2L' and '2R' the bow thruster works at full thrust.
- The lever will not stay in positions '2L' and '2R' . The lever will always
jump back to position '1L' or '1R' .
- After using the bow thruster switch the panel off.
- Switch the main switch off when leaving the ship.
Hydraulic motor
The room where the hydraulic motor of the bow thruster is installed
should be dry and well ventilated.
The hydraulic motor can be installed in various positions.
The hydraulic motor must be positioned in such a way that it is al-
ways well clear from the maximum bilge water level.
180º
ENGLISH
C
1R
2R
1L, 1R:
1
e
trap
2L, 2R:
2
e
trap
Max. bilge
water level
120201.07
7