OPERATION
Frequency of Use
If your generator will be used on an infrequent or intermittent basis, (more than
4 weeks before next use), please refer to the Battery Service section of the
SERVICING YOUR GENERATOR (see page 59) and the Fuel section of the STORAGE
chapter (see page 64) for additional information regarding battery and fuel
deterioration.
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 1 meter away from
building walls and other equipment during operation. Do not place flammable
objects close to the engine.
• Operating this generator less than 1 meter from a building or other obstruction
can cause overheating and damage the generator.
• For proper cooling, allow at least 1 meter of empty space above and around the
generator.
Keep all cooling holes open and clear of debris, mud, water, etc. Cooling holes are
located on the control panel and the bottom of the generator. If the cooling holes
are blocked, the generator may overheat and damage the engine, inverter, or
windings.
Refer to SAFE OPERATING PRECAUTIONS on page 33 and perform the IS YOUR
GENERATOR READY TO GO? checks (see page 31).
Refer to AC OPERATION (see page 40) for connecting loads to the generator.
1. Make sure that all appliances are disconnected from the AC receptacles.
34