Descargar Imprimir esta página

Honda EU70is Manual Del Propietário página 66

Ocultar thumbs Ver también para EU70is:

Publicidad

Idiomas disponibles

Idiomas disponibles

FUSE
If the fuse is blown, the starter motor will not operate.
In the event of fuse failure, locate the cause of failure and repair it before you
continue operation. If the fuse continues to fail, discontinue generator use and
consult an authorized Honda servicing dealer.
1. Turn the MAIN switch to the OFF position and remove the key before
checking or replacing the fuse.
2. Loosen the cover screw and
remove the battery maintenance
cover.
3. Remove the fuse holder cover and
pull the fuse out.
4. Replace the fuse with a fuse of the
same type and rating.
Specified fuse: 3 A, 15 A
Never use a fuse with a different
rating from that specified. Serious
damage to the electrical system or
fire may result.
5. Install the fuse holder cover and the battery maintenance cover in the reverse
order of removal (see page 60).
Never operate the generator with the battery maintenance cover open, as
poor engine and generator performance will result.
SERVICING YOUR GENERATOR
BATTERY MAINTENANCE COVER
FUSE (15 A)
FUSE HOLDER COVER
COVER
SCREW
FUSE (3 A)
63

Publicidad

loading