9.3.1. Longer Term Preventive Maintenance Activities
9.3.1.1. Verify the following activities after five years.
•
Fan air flow at the module intake, monthly
•
Power connection torque specs along the high-current
path, yearly
10. Faults and Warnings
Display
Message
ADC Reference
Low
BAT OVER
VOLTAGE
(Battery over
voltage)
5912995 A01
Message
Description
type
The ADC reference power
supply is under voltage.
Fault
Readings cannot be
trusted.
The battery voltage is too
high (i.e., above the battery
table maximum voltage
limit) to charge.
Fault
The BMID number of
battery cells setting is
incorrect.
60 of 68
Action(s)
Replace the system
controller.
Checked the battery
parameters for accuracy.
Use the ProCore App BMID
setup to set the correct
number of battery cells.
Webasto Charging Systems, Inc.
IOMM