Class of cleanliness:
Class of cleanliness
according to ISO 4406
Series
:1999
D926
20/18/15
D927
20/18/15
D936
19/16/13
D937
19/16/13
The cleanliness of the hydraulic fluid greatly influences the
functional safety and the wear and tear. In order to avoid mal-
functions and increased wear and tear, we recommend filtrat-
ing the hydraulic fluid accordingly.
Flushing instruction: Use of flushing plates or flushing valves
according to the machine manufacturer's instructions.
3 Installation
NOTICE
Damage due to dirt, moisture and ozone/UV effects
• Storage outside or under the wrong climatic conditions can
cause corrosion and other damage to the valve. Conden-
sation due to temperature fluctuations can result in elec-
tronic malfunctions.
In the case of intermediate storage, observe the follow-
ing storage conditions:
• Recommended ambient temperature: +15 to +25 °C
(+60 to +78 °F), permissible temperature: –40 to
+80 °C (–40 to +176 °F), temperature fluctuation:
< 10 °C (18 °F)
• Relative humidity: < 65 % not condensing
• Ensure there are minimal vibration and shock where
valves are stored
Following transport or storage, wait until the valves have
reached ambient temperature before starting up.
• Dirt and moisture can enter the valve through openings
and cause damage. Seals can be damaged due to the
effects of ozone and UV.
During storage and transport, seal connectors with dust
protection caps and install the shipping plate on the
mounting surface.
Remove dust protection caps and shipping plate only
shortly before mounting the valves and keep packaging
materials for future storage and transport.
Seal with protection caps any valve connectors that are
not used in operation (without mating connector).
Compare model number and type with that specified on hy-
draulic schematic. The valve can be mounted in any position,
fixed or movable.
Mounting
surface:
(< 0.01 mm (0.00004 in) over 100 mm (3.94 in)) and finish
(R
< 0.8 µm). Care must be taken to ensure that contamina-
a
tion does not enter the hydraulic system, all work areas must
be clean of surface or air-borne contamination.
Mounting: Socket head screws (grade 10.9) according to
EN ISO 4762, torque diagonally alternating.
Pattern to
Series
ISO 4401
D926
03-03-0-05
D927
05-05-0-05
D936
03-03-0-05
D937
05-05-0-05
Page 2/2
Class of cleanliness
according to ISO 4406
:1999 for longer life
17/14/11
17/14/11
17/14/11
17/14/11
Check
for
flatness
Torque
Socket
[Nm]
head screw
Pcs.
(lbf in)
M5 x 30
4
(60)
M6 x 60
4
(97)
M5 x 55
4
(60)
M6 x 60
4
(97)
4 Operating Pressure
Maximum operating pressure p
5 Electrical Connection
Electrical safety: The protective conductor connection is con-
nected to the electronics housing or valve body. The insulation
materials employed are designed for use in the safety extra-
low voltage range.
To comply with safety regulations requires isolation from the
mains according to EN 61558-1 and EN 61558-2-6 and limiting
all voltages according to EN 60204-1. We recommend using
SELV/PELV power supplies.
Rated signal: See nameplate.
External fuse per valve:
Series
D926
D927
D936
D937
Valve phasing: A positive signal (D–E) for 6+PE connector
causes valve opening PA.
Connector wiring: See wiring schematic tag attached to elec-
tronics housing or refer to the catalog.
Connection: Signal lines shielded, shielding connected at
both ends and additionally connected to reference potential
(0 V) at the control side (to improve EMC). Connect the protec-
tive conductor.
Observe technical notes TN 353 Protective Grounding and
Electric Shielding, TN426 Wiring Instructions and TN494 Maxi-
mum Permissible length of Cables.
6 Hydraulic System Start Up
Pay attention to the pressure setting, the venting instructions
and the alarm messages!
7 Service
Replacing O rings: The mounting surface O rings may be re-
placed by the customer. Pay attention to cleanliness of the
valve and of the surroundings.
Transportation/storage: Before transportation, seal the base
of the valve using a clean shipping plate or adhesive tape.
Seal the connector using a dust protection cap. Pack the valve
carefully so that it is not damaged during transportation or stor-
age.
Inspection: Following a period of storage or no operation for
more than 5 years, we recommend that the valve is inspected
by an authorized service center, in order to prevent possible
damage.
Repairs: Repairs may only be carried out by Moog or by our
authorized service centers.
8 Disposal
It is essential to comply with the relevant national waste dis-
posal regulations and environmental protection provisions
when disposing of valves, spare parts or accessories, packag-
ing that is no longer needed, hydraulic fluid or auxiliary materi-
als and substances used for cleaning!
6.8
11
6.8
11
Mounting and Installation Notes D926/7, D936/7 (B97072-D936-001; Rev. D, 05/23)
: See nameplate.
P
External fuse per valve
2.0 A time lag
3.15 A time lag
2.0 A time lag
3.15 A time lag