FAULTS

To carry out this operation, proceed as follows .
Close the gas supply tap .
1)
Pull off the knobs (A) .
2)
Remove the knob unit (B) .
3)
Undo the screws (C) and remove the control
4)
panel (D) .
Undo the screw (E) of the pressure test point .
5)
Connect the pressure gauge (F) to the pres-
6)
sure test point (G) .
Open again the gas supply tap .
7)
See section "TROUBLESHOOTING" of the User
instruction manual .
3413940_inst_GB

CHECKING THE GAS PRESSURE

B
A
C
FAULTS

TROUBLESHOOTING

Fill the jacket (see "User instructions ma-
8)
nual") .
Light the burner and turn the knobs to the
9)
full flame setting (see "User instructions ma-
nual") , then check that the pressure reading
complies with the values in the table (see at
the end of the manual) .
Turn off the burner, disconnect the pressure
10)
gauge .
Restore the initial conditions after completing
11)
the operation .