FAULT
The appliance has been tested before being put
into service . The information provided below
is intended to assist in the identification and
correction of any anomalies and malfunctions
which might occur during use .
The user can solve some of these problems
himself, but for others specific technical knowl-
edge or skill is required, and so they must only
be carried out by qualified staff with recog-
nised experience acquired in the specific sector
of operation .
Faults
Smell of gas
The pilot lamp does not
light upsi accende .
The pilot light goes off .
The flame is yellow .
The pressure gauge has
detected an abnormal
pressure (> 0,5 bar)
inside the jacket
The safety thermostat is
tripped too often
Burner control knob is
stiff
3413940_ut_GB
FAULT
TROUBLESHOOTING
Causes
Occasional leak because
flame has gone off .
The spark ignition devices
are not working .
Air in pipelines due to long
period of downtime .
The thermocouple has not
heated up enough .
Burner dirty, heat exchange
pipes clogged, condensation
drips .
Pressure control valve fou-
led or damaged
The water level in the jacket
is not correct
Gas control valve
malfunction
NOTE:
For any need, please contact Angelo Po's
agents or headquarters, which can be found
in the contacts section of the website www .
angelopo .com .
Close the gas supply tap and venti-
Check that the ignition devices are
in good working order . Light by
hand with a naked light .
NOTE: Contact the after-
sales service .
Make more attempts to light the
flame .l'operazione di accensione .
Make more attempts to light the
NOTE: Contact the after-
sales service .
Clean the pressure control valve
and call the after-sales service if
Restore the water level in the jacket;
if necessary call the aftersales
NOTE: Contact the after-
sales service .
ENGLISH
Remedies
late the room .
flame .
necessary
service