Descargar Imprimir esta página

Angelo Po 1S1PI1G Manual De Uso página 168

Marmita indirecta 'gas'

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
To carry out this operation, proceed as follows .
Fit the spanner (A) onto the hexagon (B) .
1)
Keep a firm grip on the spanner (A) and undo
2)
the locking screws (C) .
Turn the spanner (A) clockwise to load the
3)
spring or anti-clockwise to release it ( left
hand) and anti-clockwise to load the spring
or clockwise to release it ( right hand) .
C
B
A
To carry out this operation, proceed as follows .
Close the gas supply tap .
1)
Pull off the knobs (A) .
2)
Remove the knob unit (B) .
3)
Undo the screws (C) and remove the control
4)
panel (D) .
Undo the screws (E) and extract the cap (F) .
5)
Pull off the cone (G) .
6)
Clean the cone (G) and its seat .
7)
Coat the cone with grease (G), fit it in its seat
8)
and turn it a few times .
Pull off the cone (G) to remove the excess
9)
grease .
After completing the operation, fit the cone
10)
(G), the cap (F), the control panel (D) and the
knobs (A-B) .
16
ADJUSTING THE LID COUNTER-BALANCING
GREASING THE GAS TAP
in the screws (C) without tightening them
4)
fully .
the spanner (A) to turn the shaft until it is lo-
5)
cated in one of the seats provided .
Fully tighten the screws (C) .
6)
D
C
B
A
C
ADJUSTMENTS
C
B
A
F
G
E
3413940_inst_GB

Publicidad

loading